Registry

Carbon Monoxide Detector Requirements by State: Who Must Install, When, and Where

A registry built from statute and code text in force on November 15, 2026, sized with 2025 population and 2020 household energy microdata.
Primary data
KBR registry of state CO alarm statutes and rules (coded from opened text); Census Vintage 2025 population; EIA RECS 2020 v7 microdata
Data period
Laws in force on 2026-11-15; population July 1, 2025; households 2020
Latest release used
2026-03-26
Next release
Census Vintage 2026 estimates, expected 2027; registry rechecked each quarter
Geography
50 states and the District of Columbia
Sources
34 (32 Tier 1)
Short answer

35.1 percent of Americans, 119.9 million people, live where carbon monoxide detector requirements reach existing owner-occupied homes: 7 jurisdictions require alarms now and 9 states at sale, by our reading of statute text in force on November 15, 2026. 5 more states cover only rentals, 5 only new homes, and 22 had no state law we could verify.

35.1%of Americans (119.9 million) live where a verified state law reaches existing owner-occupied homes, now or at sale (2025 population, laws as of 2026-11-15)[1][6][7][8]
62.5 millionhouseholds with a CO source (61.7% of them) live where no existing-house rule was verified (RECS 2020)[1][2]
82.0%of U.S. households burn gas, propane, oil or wood or have an attached garage (RECS 2020)[2]
400+Americans die each year from unintentional non-fire CO poisoning (CDC)[3]

State carbon monoxide alarm laws, coded from official text

Checked Quarterly. Last checked 2026-11-15. Entries are neutral records of public data; each links to its source record.

StateReach and citationDateEvidenceSource
AlaskaLaw not opened: AS 18.70.095not openednamed in official record, text not openedRecord
ArkansasNew construction only: Act 146 of 2011 (HB 1385)2011-02-24agency record (bill record and title)Record
CaliforniaExisting homes, no trigger: Health and Safety Code 179262011-07-01agency recordRecord
ColoradoExisting homes at sale: C.R.S. 38-45-101 to 38-45-1062009-07-01agency recordRecord
ConnecticutNew construction only: C.G.S. 29-292 and 29-315b2005-10-01agency recordRecord
District of ColumbiaExisting homes, no trigger: D.C. Code 6-751.022016-05-18agency recordRecord
FloridaNew construction only: Fla. Stat. 553.8852008-07-01agency recordRecord
GeorgiaNew construction only: Georgia amendments to the IRC, R313.42009-01-01agency recordRecord
IllinoisLaw not opened: 430 ILCS 135 (Carbon Monoxide Alarm Detector Act)not openednamed in official record, text not openedRecord
IowaExisting homes, no trigger: Iowa Code 10A.518(3)2018-07-01agency recordRecord
LouisianaExisting homes at sale: La. R.S. 40:1581 (Acts 2022, No. 458)2022 (Act 458)agency recordRecord
MaineExisting homes at sale: 25 M.R.S. 24682009-10-31agency recordRecord
MarylandRentals or multifamily only: Md. Public Safety 12-11042018-04-01agency recordRecord
MassachusettsExisting homes, no trigger: M.G.L. c. 148, s. 26F1/2not stated in opened textagency recordRecord
MichiganNew construction only: MCL 125.1504f (Overbeck law)2009-03-23agency recordRecord
MinnesotaExisting homes, no trigger: Minn. Stat. 299F.512006 (enacted)agency recordRecord
MontanaRentals or multifamily only: MCA 70-24-303(1)(g)2009 (Ch. 43, L. 2009)agency recordRecord
NebraskaExisting homes at sale: Carbon Monoxide Safety Act, LB 34 (2015)2017-01-01agency recordRecord
New HampshireRentals or multifamily only: RSA 153:10-a2010-01-01agency recordRecord
New JerseyExisting homes at sale: N.J.A.C. 5:70-4.19(d)not stated in opened textagency recordRecord
New YorkExisting homes, no trigger: Executive Law 378(5-a)not stated in opened textagency recordRecord
North CarolinaRentals or multifamily only: G.S. 42-42(a)(7)2009 (S.L. 2009-279)agency recordRecord
OregonExisting homes at sale: ORS 105.836 to 105.8442009 c.591agency recordRecord
PennsylvaniaLaw not opened: Carbon Monoxide Alarm Standards Act, Act 121 of 20132013-12-18named in official record, text not openedRecord
Rhode IslandExisting homes at sale: Rhode Island Fire Code, chapter 24 (one- and two-family dwellings)not stated in opened textagency recordRecord
VermontExisting homes at sale: 9 V.S.A. 2881 to 28832005-07-01agency recordRecord
WashingtonExisting homes at sale: RCW 19.27.530; WAC 51-51-03152009-07-26agency recordRecord
West VirginiaRentals or multifamily only: W. Va. Code 15A-10-12not stated in opened textagency recordRecord
WisconsinExisting homes, no trigger: Wis. Stat. 101.647 and 101.1492009 Act 158agency recordRecord

Carbon monoxide detector requirements reach existing houses for 35.1 percent of Americans

We coded the residential reach of each state's CO alarm law from the statute or rule text and summed Census Vintage 2025 population by group. 119.9 million of 341.8 million residents live in the 16 jurisdictions whose law reaches an owner-occupied existing house, either now or when it is sold.

How far each state's CO law reaches

4 = existing homes now, 3 = at sale, 2 = rentals only, 1 = new homes only, 0 = none verified; AK, IL, PA blank (not opened)

How far each state's CO law reachesUS tile map of carbon monoxide alarm laws: 7 jurisdictions require alarms in existing homes now, 9 at sale, 5 rentals only, 5 new homes only and 22 have no state law verified.AKME: 3ME3VT: 3VT3NH: 2NH2WA: 3WA3ID: 0ID0MT: 2MT2ND: 0ND0MN: 4MN4ILWI: 4WI4MI: 1MI1NY: 4NY4RI: 3RI3MA: 4MA4OR: 3OR3NV: 0NV0WY: 0WY0SD: 0SD0IA: 4IA4IN: 0IN0OH: 0OH0PANJ: 3NJ3CT: 1CT1CA: 4CA4UT: 0UT0CO: 3CO3NE: 3NE3MO: 0MO0KY: 0KY0WV: 2WV2VA: 0VA0MD: 2MD2DE: 0DE0AZ: 0AZ0NM: 0NM0KS: 0KS0AR: 1AR1TN: 0TN0NC: 2NC2SC: 0SC0DC: 4DC4OK: 0OK0LA: 3LA3MS: 0MS0AL: 0AL0GA: 1GA1HI: 0HI0TX: 0TX0FL: 1FL1PR0 to 00 to 00 to 11 to 33 to 33 to 4reach score

Source: KBR coding of statute and rule text opened 2026-11-15

7 jurisdictions (California, the District of Columbia, Iowa, Massachusetts, Minnesota, New York and Wisconsin) put the duty on owners of existing homes with no sale or permit needed. They hold 82.2 million people, 24.1 percent of the U.S. population in 2025.

9 states (Colorado, Louisiana, Maine, Nebraska, New Jersey, Oregon, Rhode Island, Vermont and Washington) reach existing houses at sale or transfer. They hold 37.6 million people, 11.0 percent.

The largest single block is the 22 jurisdictions where this check verified no statewide CO alarm statute or rule: 121.9 million people, 35.7 percent, led by Texas and Ohio. Many of them still require CO alarms in new homes through an adopted International Residential Code (section R315), and cities can add their own rules.

Population by reach of state CO law

Millions of residents, July 1, 2025

Population by reach of state CO lawBar chart: 82.2 million people live where existing homes need CO alarms now, 37.6 million at sale, 21.8 million rentals only, 51.7 million new homes only, 26.5 million where the law was not opened and 121.9 million where no state law was verified.million peopleExisting homes now82.2At sale37.6Rentals only21.8New homes only51.7Law not opened26.5None verified122

Source: U.S. Census Bureau Vintage 2025; KBR registry

Who lives under which kind of CO alarm law, 2025 population Download CSV
GroupJurisdictionsPopulation (millions)Share of U.S. %CO-source homes (millions)
Existing homes, no trigger782.224.127.5
Existing homes at sale937.611.011.3
Rentals or multifamily only521.86.45.7
New construction only551.715.113.6
Law not opened326.57.89.2
No state CO law verified22121.935.734.1
All 50 states and DC51341.8100101.2

Population: Census Vintage 2025. CO-source homes: RECS 2020 households with combustion fuel or attached garage, summed by state.

Source: [1][2] U.S. Census Bureau; U.S. Energy Information Administration

The state-by-state registry, with citation, date and placement

Each row comes from the statute, regulation or state code amendment we opened, saved and coded on 2026-11-15. Rows without opened text say so.

Carbon monoxide alarm laws by state, coded from statute and rule text (in force 2026-11-15) Download CSV
Show all 51 rows
StateCodeGroupCitationEffectiveDwellings and triggersPlacementPopulation 2025Homes with CO source %
AlabamaALNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check5,193,08870.8
AlaskaAKLaw not openedAS 18.70.095not openedSection text not opened: the official statutes site returned an application shell without the section textNot verified737,27091.7
ArizonaAZNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check7,623,81880.6
ArkansasARNew construction onlyAct 146 of 2011 (HB 1385)2011-02-24Act title: low voltage CO detectors in new home constructionNot stated in opened record3,114,79178.0
CaliforniaCAExisting homes, no triggerHealth and Safety Code 179262011-07-01Each existing dwelling unit with a fossil fuel heater or appliance, fireplace or attached garage: single-family by July 1, 2011, other units by January 1, 2013, hotels and motels by January 1, 2017Per state building standards or manufacturer instructions39,355,30993.3
ColoradoCOExisting homes at saleC.R.S. 38-45-101 to 38-45-1062009-07-01Existing single-family and multifamily units at sale or transfer, at permitted interior alterations or fuel-fired appliance replacement, and rentals at each change in tenant occupancyWithin 15 feet of the entrance to each sleeping room6,012,56192.2
ConnecticutCTNew construction onlyC.G.S. 29-292 and 29-315b2005-10-01New one- and two-family homes with a building permit for new occupancy issued on or after October 1, 2005; school buildings; temporary battery alarms during permitted interior alterations or additionsPer Fire Safety Code; temporary units in the vicinity of the work3,688,49691.4
DelawareDENo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check1,059,95281.9
District of ColumbiaDCExisting homes, no triggerD.C. Code 6-751.022016-05-18Owner of each new and existing occupied dwelling unit installs CO detectors per the Construction Codes (D.C. Law 21-118)Per Construction Codes693,64577.4
FloridaFLNew construction onlyFla. Stat. 553.8852008-07-01Buildings and additions constructed on or after July 1, 2008 with a fossil-fuel heater or appliance, fireplace or attached garage; existing buildings under alteration exempt unless the work is an additionWithin 10 feet of each room used for sleeping23,462,51858.5
GeorgiaGANew construction onlyGeorgia amendments to the IRC, R313.42009-01-01New one- and two-family dwellings under the state minimum code (amendment text opened is the 2009 revision)General vicinity of each sleeping area11,302,74878.5
HawaiiHINo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check1,432,82060.4
IdahoIDNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check2,029,73384.3
IllinoisILLaw not opened430 ILCS 135 (Carbon Monoxide Alarm Detector Act)not openedSection text not opened: the official site and its archive copies did not respond to repeated attempts on 2026-11-15; not codedNot verified12,719,14190.7
IndianaINNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check6,973,33390.1
IowaIAExisting homes, no triggerIowa Code 10A.518(3)2018-07-01New single-family and multiple-unit construction begun on or after July 1, 2018; existing single-family dwellings, single-family rentals and multiple-unit buildings with a fuel-fired heater or appliance, fireplace or attached garagePer rules of the director3,238,38792.5
KansasKSNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check2,977,22087.7
KentuckyKYNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check4,606,86472.9
LouisianaLAExisting homes at saleLa. R.S. 40:1581 (Acts 2022, No. 458)2022 (Act 458)All existing one- or two-family dwellings at the time of sale or lease; home generator installationsNot specified4,618,18966.9
MaineMEExisting homes at sale25 M.R.S. 24682009-10-31Multifamily units, dormitories, lodging; new single-family construction, added bedrooms and conversions; single-family and multiapartment buildings acquired by sale after October 31, 2009Each area within, or giving access to, bedrooms1,414,87493.0
MarylandMDRentals or multifamily onlyMd. Public Safety 12-11042018-04-01Rental dwelling units from April 1, 2018; hotels, lodging and rooming houses from April 1, 2017; other dwellings subject to the subtitleOutside each sleeping area; rentals also on every level including the basement6,265,34775.7
MassachusettsMAExisting homes, no triggerM.G.L. c. 148, s. 26F1/2not stated in opened textEvery dwelling occupied in whole or part for residential purposes with fossil-fuel burning equipment or enclosed parking; landlord installs at the start of any rental periodPer Board of Fire Prevention Regulations7,154,08490.3
MichiganMINew construction onlyMCL 125.1504f (Overbeck law)2009-03-23Initial construction, permitted renovation of an existing single-family home, or an added bedroom, as provided by the directorVicinity of bedrooms, near an attached garage and fuel-burning appliances10,127,88494.7
MinnesotaMNExisting homes, no triggerMinn. Stat. 299F.512006 (enacted)Every single-family dwelling and every multifamily dwelling unit; hotel and lodging guest roomsWithin 10 feet of each sleeping room5,830,40592.7
MississippiMSNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check2,954,16071.3
MissouriMONo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check6,270,54181.1
MontanaMTRentals or multifamily onlyMCA 70-24-303(1)(g)2009 (Ch. 43, L. 2009)Each rental dwelling unit under the landlord's control; landlord verifies at the start of a rental agreementPer Department of Labor and Industry rules1,144,69484.1
NebraskaNEExisting homes at saleCarbon Monoxide Safety Act, LB 34 (2015)2017-01-01New dwellings from January 1, 2017; single-family dwellings offered for sale; permitted interior alterations, repairs, fuel-fired appliance replacements or additionsEach habitable floor, or per adopted building code2,018,00687.3
NevadaNVNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check3,282,18886.5
New HampshireNHRentals or multifamily onlyRSA 153:10-a2010-01-01Multi-unit dwellings and rental units with an attached garage or combustion appliance; single-family homes built or substantially rehabilitated after January 1, 2010Per NFPA 7201,415,34293.8
New JerseyNJExisting homes at saleN.J.A.C. 5:70-4.19(d)not stated in opened textOne- and two-family dwellings with a fuel-burning device or attached garage that are subject to the certificate required at sale or change of occupancy (N.J.A.C. 5:70-2.3)Immediate vicinity of the sleeping areas9,548,21590.7
New MexicoNMNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check2,125,49896.2
New YorkNYExisting homes, no triggerExecutive Law 378(5-a)not stated in opened textEvery one- or two-family dwelling, condominium or cooperative unit and multiple dwelling with a CO-emitting appliance or attached garagePer Code Council standards20,002,42794.1
North CarolinaNCRentals or multifamily onlyG.S. 42-42(a)(7)2009 (S.L. 2009-279)Rental units with a fossil-fuel burning heater, appliance, fireplace or attached garageOne per rental unit per level11,197,96863.6
North DakotaNDNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check799,35879.6
OhioOHNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check11,900,51089.2
OklahomaOKNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check4,123,28884.1
OregonORExisting homes at saleORS 105.836 to 105.8442009 c.591No conveyance of a one- and two-family dwelling or multifamily housing with a CO source unless alarms are installedDetection for all sleeping areas, per State Fire Marshal rules4,273,58673.1
PennsylvaniaPALaw not openedCarbon Monoxide Alarm Standards Act, Act 121 of 20132013-12-18Act record opened (enacted December 18, 2013, effective immediately); section text did not load, so scope is not codedNot verified13,059,43287.3
Rhode IslandRIExisting homes at saleRhode Island Fire Code, chapter 24 (one- and two-family dwellings)not stated in opened textNew and converted residential buildings; all occupied residential properties before title is transferred, at the seller's responsibilityPer NFPA 72, 2019 edition, and fire code 24.3.4.21,114,52193.3
South CarolinaSCNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check5,570,27463.3
South DakotaSDNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check935,09485.1
TennesseeTNNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check7,315,07667.6
TexasTXNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check31,709,82174.8
UtahUTNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check3,538,90491.6
VermontVTExisting homes at sale9 V.S.A. 2881 to 28832005-07-01Newly constructed single-family dwellings and any single-family dwelling transferred by sale or exchangeVicinity of any bedrooms644,66397.2
VirginiaVANo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check8,880,10774.7
WashingtonWAExisting homes at saleRCW 19.27.530; WAC 51-51-03152009-07-26All residential occupancies (new by January 1, 2011, others by January 1, 2013) except owner-occupied single-family homes occupied before July 26, 2009, which must be equipped when soldOutside each sleeping area near the bedrooms and on each level8,001,02064.8
West VirginiaWVRentals or multifamily onlyW. Va. Code 15A-10-12not stated in opened textNewly constructed residential units with a fuel-burning heating or cooking source; rented or leased one- and two-family dwellings, apartments, hotels and dormitories; schools and day careAreas adjoining rooms with fuel-burning appliances1,766,14773.7
WisconsinWIExisting homes, no triggerWis. Stat. 101.647 and 101.1492009 Act 158Owner of every one- or two-family dwelling with an attached garage, fireplace or fuel-burning appliance; units with fuel-burning appliances in public buildings used for sleepingBasement and each floor level except attic, garage or storage area5,972,78789.9
WyomingWYNo state CO law verifiednone verifiedNo statewide CO alarm statute or rule verified in this check588,75390.5

Group = strongest residential rule in the text opened. Population: Census Vintage 2025. Homes with CO source: RECS 2020 share of households using gas, propane, fuel oil or wood, or with an attached garage.

Source: [1][2][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32] U.S. Census Bureau; U.S. Energy Information Administration; Washington State Legislature; California Legislative Information; Council of the District of Columbia; Iowa Legislature; Massachusetts Legislature; Minnesota Office of the Revisor of Statutes; New York State Senate; Wisconsin Legislature; Colorado Office of Legislative Legal Services; Louisiana State Legislature; Maine Legislature; Nebraska Legislature; Cornell Law School LII, text of New Jersey Uniform Fire Code; Oregon State Legislature; Rhode Island Fire Safety Code Board of Appeal and Review; Vermont General Assembly; Maryland General Assembly; Montana Legislature; North Carolina General Assembly; New Hampshire General Court; West Virginia Legislature; Arkansas State Legislature; Connecticut General Assembly; Florida Legislature; Georgia Department of Community Affairs; Michigan Legislature; Pennsylvania General Assembly

CO source: Most laws apply only to homes with a fuel-burning heater or appliance, a fireplace or an attached garage. An all-electric home with no attached garage is usually exempt.

Gas water heater and furnace in a basement with a plug-in alarm nearby
Illustrative photograph. Generated image, not a specific project.

Selling the house is the trigger in Colorado, Oregon and 7 more states

Sale-trigger laws put the duty on the seller or buyer at closing rather than on every owner at once.

  • Colorado: the seller of an existing single-family home offered for sale on or after July 1, 2009, with a fuel-fired heater or appliance, fireplace or attached garage, must make sure an operational alarm is within 15 feet of the entrance to each sleeping room (C.R.S. 38-45-102).
  • Oregon: a one- and two-family dwelling with a CO source may not be conveyed unless alarms cover all sleeping areas; a buyer can recover the greater of actual damages or $250 per unit (ORS 105.838 and 105.840).
  • Maine: a buyer of a single-family home acquired after October 31, 2009 installs CO detectors within 30 days and certifies this at closing (25 M.R.S. 2468).
  • Washington: owner-occupied houses occupied before July 26, 2009 are exempt until sold; the seller then equips them (RCW 19.27.530).
  • Louisiana: existing one- or two-family dwellings must contain an operable CO detector with a long-life sealed battery at the time of sale or lease (La. R.S. 40:1581, Acts 2022, No. 458).
  • Rhode Island, Vermont, Nebraska and New Jersey attach the rule to transfer of title or a certificate at sale or change of occupancy.

Five states stop at rental units and apartment buildings

Maryland, Montana, New Hampshire, North Carolina and West Virginia reach existing rentals or multifamily buildings, not owner-occupied houses. They hold 21.8 million people, 6.4 percent.

North Carolina requires landlords to provide at least 1 operable CO alarm per rental unit per level in units with a fossil-fuel heater, appliance, fireplace or attached garage (G.S. 42-42(a)(7)). Montana requires a landlord-installed CO detector in each dwelling unit, checked at the start of each rental agreement (MCA 70-24-303).

Maryland rental units need an alarm outside each sleeping area and on every level, including the basement, from April 1, 2018 (Public Safety 12-1104). New Hampshire covers multi-unit dwellings and rental units, and single-family homes built or substantially rehabilitated after January 1, 2010 (RSA 153:10-a).

Landlord rules also sit inside the broader laws: Massachusetts, Minnesota, Colorado and Iowa all name landlords or rental owners. Landlords should read the full statute in their state; this table is not legal advice.

Florida, Georgia and 3 more write CO rules for new homes only

Arkansas, Connecticut, Florida, Georgia and Michigan reach new construction (and in Michigan, permitted renovation) but not existing homes in general. They hold 51.7 million people, 15.1 percent.

Florida requires an alarm within 10 feet of each sleeping room in buildings and additions built on or after July 1, 2008 with a fossil-fuel appliance, fireplace or attached garage, and states that existing buildings under alteration or repair are exempt unless the work is an addition (Fla. Stat. 553.885).

Connecticut covers one- and two-family homes with a permit for new occupancy issued on or after October 1, 2005 (C.G.S. 29-292). Georgia added CO alarms to its state one- and two-family code effective January 1, 2009.

A permit for a kitchen or bath remodel can bring CO alarms into an older house

The International Residential Code section R315 applies to existing dwellings when permitted alterations, repairs or additions occur, and several states wrote the same trigger into statute.

Washington's adopted text of section R315.2.2 says existing dwellings shall be equipped with CO alarms, with an inspection where alterations, repairs or additions requiring a permit occur, or where a sleeping room is added. Its 3 exceptions cover exterior-only work, non-fuel plumbing, mechanical or electrical work, and owner-occupied homes occupied before July 26, 2009 (WAC 51-51-0315).

Colorado and Nebraska apply the same trigger by statute to interior alterations, repairs, fuel-fired appliance replacements or additions that need a permit. Connecticut requires temporary battery CO alarms while an occupied one- or two-family home is under permitted interior alterations or additions (C.G.S. 29-315b).

Remodel triggers: when a permit pulls CO alarms into an existing home Download CSV
JurisdictionWhat triggers alarms in an existing homeExemptions in the textCitation
Washington (IRC R315.2.2 as adopted)Alterations, repairs or additions requiring a permit, or an added sleeping roomExterior-only work; non-fuel plumbing, mechanical or electrical work; owner-occupied homes occupied before July 26, 2009WAC 51-51-0315
ColoradoInterior alterations, repairs, fuel-fired appliance replacements or additions requiring a permit, or added sleeping rooms, on or after July 1, 2009Not listed in the section openedC.R.S. 38-45-102 to 104
NebraskaInterior alteration, repair, fuel-fired appliance replacement or addition requiring a permit, on or after January 1, 2017Exterior alterationsLB 34 sec. 4
MichiganRenovation of an existing single-family dwelling requiring a permit, or an added bedroomApplies as provided by the directorMCL 125.1504f
MaineAddition or restoration that adds at least 1 bedroom; conversion to a dwellingNone stated25 M.R.S. 2468
ConnecticutTemporary battery CO alarms during permitted interior alterations or additions while occupiedHomes without a fuel-burning appliance, fireplace or attached garageC.G.S. 29-315b
FloridaAdditions onlyExisting buildings under alteration or repairFla. Stat. 553.885

Not legal advice. Local building departments decide what needs a permit.

Source: [5][14][17][31][16][28][29] Washington State Legislature; Colorado Office of Legislative Legal Services; Nebraska Legislature; Michigan Legislature; Maine Legislature; Connecticut General Assembly; Florida Legislature

For a homeowner this means the inspection for a gas range swap, a new water heater or a bedroom addition can include a CO alarm check. Plan it into the kitchen remodel timeline and ask the contractor who pulls the permit; see how to choose a remodeling contractor. Related rules: smoke detector requirements and GFCI requirements.

Where the alarm goes: within 10 feet, 15 feet, or on every level

The laws agree on the area near bedrooms and differ on distance and levels.

Where the alarm has to go: placement rules written into the text Download CSV
JurisdictionPlacement ruleCitation
MinnesotaWithin 10 feet of each room used for sleepingMinn. Stat. 299F.51
FloridaWithin 10 feet of each room used for sleeping (new buildings and additions)Fla. Stat. 553.885
ColoradoWithin 15 feet of the entrance to each sleeping roomC.R.S. 38-45-102
Washington (IRC R315 as adopted)Outside each separate sleeping area near the bedrooms, and on each levelWAC 51-51-0315
WisconsinBasement and each floor level except attic, garage or storage areaWis. Stat. 101.647
NebraskaEach habitable floor, or per adopted building codeLB 34 (2015)
Maryland rentalsOutside each sleeping area and on every level, including the basementPublic Safety 12-1104(c)
Maryland, central alarm systemWithin 25 feet of any CO-producing fixturePublic Safety 12-1104(d)
MaineEach area within, or giving access to, bedrooms25 M.R.S. 2468
North Carolina rentalsAt least 1 per rental unit per levelG.S. 42-42(a)(7)
MichiganVicinity of bedrooms, near an attached garage and fuel-burning appliancesMCL 125.1504f

Text as opened 2026-11-15. Several laws defer to the manufacturer, NFPA 720 or the adopted building code.

Source: [11][29][14][5][13][17][22][16][24][31] Minnesota Office of the Revisor of Statutes; Florida Legislature; Colorado Office of Legislative Legal Services; Washington State Legislature; Wisconsin Legislature; Nebraska Legislature; Maryland General Assembly; Maine Legislature; North Carolina General Assembly; Michigan Legislature

Minnesota and Florida use 10 feet from each sleeping room. Colorado uses 15 feet from the entrance to each sleeping room. Washington's IRC text, Wisconsin, Nebraska and Maryland rentals add every level. Several laws defer to the manufacturer's instructions or NFPA 720, so the box insert is part of the rule.

82.0 percent of homes have a CO source, including 67.4 percent of homes with an electric range

RECS 2020 microdata show that a CO source is the norm: 82.0 percent of 123.5 million households use gas, propane, fuel oil or wood, or have an attached garage.

What puts CO in a home

Share of U.S. households, 2020

What puts CO in a homeBar chart: 82.0 percent of households have a combustion fuel or attached garage, 74.8 percent burn a fuel, 61.0 percent use natural gas, 60.8 percent heat mainly with a fuel, 36.2 percent cook with gas or propane and 53.1 percent cook on an electric range.percentFuel or garage82.0Any fuel burned74.8Natural gas61.0Fuel main heat60.8Gas range36.2Electric range53.1Garage, no fuel7.2

Source: EIA RECS 2020 microdata, KBR tabulation

74.8 percent of U.S. households used a combustion fuel in 2020 and 61.0 percent used natural gas (EIA RECS 2020). 60.8 percent heated mainly with a combustion fuel and 36.2 percent cooked on a gas or propane range.

An electric stove does not settle the question. 53.1 percent of households cooked on an electric range, and 67.4 percent of them, about 44.2 million households, still had a gas, propane, oil or wood source or an attached garage. Only 18.0 percent of households had neither. See induction vs gas stove and gas stove rules for the stove side.

Most homes have something that can make carbon monoxide (RECS 2020) Download CSV
Household characteristicShare of U.S. households %Standard error (points)
Combustion fuel or attached garage82.00.1
Uses gas, propane, fuel oil or wood74.80.1
Uses natural gas61.00.1
Main heat from a combustion fuel60.80.1
Cooks on a gas or propane range36.20.1
Cooks on an electric range53.10.1
Electric range, still has a CO source (of electric-range homes)67.40.1
Attached garage, no combustion fuel7.20.1
Single-family homes with a CO source (of single-family)92.70.1

EIA RECS 2020 v7 microdata, 18,496 records, NWEIGHT, standard errors from 60 replicate weights. Fuel use is any end use reported for the home.

Source: [2] U.S. Energy Information Administration

Kitchen under renovation with a gas range waiting to be connected
Illustrative photograph. Generated image, not a specific project.

62.5 million homes with a CO source sit outside any verified existing-house rule

Overlaying RECS 2020 state estimates on the registry puts 61.7 percent of CO-source households in jurisdictions with no verified rule for existing owner-occupied houses.

Homes with a CO source, by law group

Millions of households, RECS 2020

Homes with a CO source, by law groupColumn chart of households with a combustion fuel or attached garage: 27.5 million in states requiring alarms in existing homes now, 11.3 million at sale, 5.7 million rentals only, 13.6 million new only, 9.2 million not opened and 34.1 million with no state law verified.010.020.030.040.0million households27.5Now11.3At sale5.7Rentals13.6New only9.2Not opened34.1None

Source: EIA RECS 2020 microdata; KBR registry

Group E alone, with no state CO law verified, holds 34.1 million CO-source households, 33.6 percent of the U.S. total. Texas has 7.7 million and Ohio 4.2 million. New Mexico has the highest CO-source share in that group at 96.2 percent of households.

No state CO law verified: largest gaps

Households with a CO source, millions, RECS 2020

No state CO law verified: largest gapsBar chart of states with no verified CO alarm law: Texas has 7.7 million households with a CO source, Ohio 4.2 million, Virginia 2.4 million and Indiana 2.3 million.million householdsTexas7.7Ohio4.2Virginia2.4Indiana2.3Arizona2.2Missouri2Tennessee1.8Alabama1.3

Source: EIA RECS 2020 microdata; KBR registry

More than 400 deaths a year: the CDC count behind these laws

CDC and CPSC publish rounded national lower bounds for unintentional, non-fire CO poisoning.

Carbon monoxide poisoning: national figures as published Download CSV
MeasureValueScopePublisher
Deaths per year (more than)400Unintentional, not linked to firesCDC
Emergency department visits per year (more than)100,000Unintentional, not linked to firesCDC
Hospitalizations per year (more than)14,000Unintentional, not linked to firesCDC
Deaths per year (more than)200Accidental, non-fire, consumer productsCPSC
Of which portable generators (more than)100Consumer productsCPSC
ED visits per death (indicative)250Ratio of CDC lower boundsKBR calculation

CDC and CPSC publish rounded lower bounds without a single reference year on these pages.

Source: [3][4] Centers for Disease Control and Prevention; U.S. Consumer Product Safety Commission

CDC says that each year more than 400 Americans die from unintentional CO poisoning not linked to fires, more than 100,000 visit an emergency department and more than 14,000 are hospitalized. CPSC counts more than 200 deaths a year tied to consumer products, more than 100 of them to portable generators. For fires that start in the kitchen, see kitchen fire statistics; for kitchen ventilation, see range hood CFM.

Counts and distributions

Population share by reach of state CO alarm law (signature)

Formulasum of Census Vintage 2025 POPESTIMATE2025 for jurisdictions in each group / population of 50 states and DC x 100

Inputs: fact rows for group populations and total; registry.csv (fact sheet rows)

Result: Existing homes now 24.1%, at sale 11.0%, rentals only 6.4%, new only 15.1%, not opened 7.8%, none verified 35.7%; existing houses reached now or at sale 35.1% (119.9 million)

Roughly a third of Americans live where a state law reaches the house they already own; the largest block, 35.7 percent, lives where no state law was verified.

Limitations: Group reflects the strongest rule in the text we opened; local ordinances and adopted building codes are not counted; three laws were not opened.

CO-source households outside any verified existing-house rule

Formulasum over states in groups C, D, U and E of RECS 2020 weighted households with USENG, USELP, USEFO or USEWOOD = 1 or PRKGPLC1 = 1

Inputs: RECS 2020 v7 microdata; registry.csv (fact sheet rows)

Result: 62.5 million households, 61.7 percent of 101.2 million CO-source households

Most homes that could produce CO are not covered by an existing-house state rule.

Limitations: 2020 households against 2026 law; RECS state estimates carry sampling error.

Electric-range homes that still have a CO source

Formulaweighted households with RANGEFUEL = 5 and a CO source / weighted households with RANGEFUEL = 5 x 100

Inputs: RECS 2020 v7 (fact sheet rows)

Result: 67.4 percent (44.2 million households)

Switching the range to electric rarely removes the last CO source in a home.

Limitations: Fuel use variables do not say where the appliance is or whether it is vented.

Emergency department visits per CO death

FormulaCDC ED visits (more than 100,000) / CDC deaths (more than 400)

Inputs: fact rows for CDC deaths and ED visits (fact sheet rows)

Result: 250 visits per death (indicative)

Non-fatal poisonings far outnumber deaths.

Limitations: Both inputs are rounded lower bounds.

Download the calculations (CSV)

Key findings

  1. 35.1 percent of U.S. residents (119.9 million) lived in 2025 in jurisdictions where a verified state law reaches existing owner-occupied houses, now or at sale.[1][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32]
  2. California, D.C., Iowa, Massachusetts, Minnesota, New York and Wisconsin put the duty on owners of existing homes with a CO source: 82.2 million people in 2025.[1][7][8][9][10][11][12][13]
  3. Texas and Ohio are the most populous of the 22 jurisdictions with no state CO alarm law verified; the group holds 121.9 million people (35.7 percent).[1]
  4. 62.5 million U.S. households with a CO source (61.7 percent) sit outside any verified existing-house rule (RECS 2020 overlaid on 2026 law).[1][2]
  5. California required CO devices in existing single-family homes with a fossil fuel appliance, fireplace or attached garage by July 1, 2011, and in hotel and motel units by January 1, 2017.[7]
  6. Minnesota requires an alarm within 10 feet of each room used for sleeping in every single-family dwelling and multifamily unit.[11]
  7. Colorado sellers of existing homes offered on or after July 1, 2009 must have an alarm within 15 feet of the entrance to each sleeping room.[14]
  8. Oregon buyers can recover the greater of actual damages or $250 per unit if a seller conveys a home with a CO source without alarms.[19]
  9. Washington's IRC R315.2.2 text requires CO alarms in existing dwellings when permitted alterations, repairs or additions occur, with 3 exceptions.[5]
  10. Florida's CO law covers buildings and additions built on or after July 1, 2008 and exempts existing buildings under alteration unless the work is an addition.[29]
  11. 82.0 percent of U.S. households used a combustion fuel or had an attached garage in 2020; 18.0 percent had neither.[2]
  12. 67.4 percent of electric-range households, about 44.2 million, still had a combustion fuel or attached garage in 2020.[2]
  13. CDC reports more than 400 deaths, more than 100,000 emergency department visits and more than 14,000 hospitalizations a year from unintentional non-fire CO poisoning.[3]
  14. CPSC counts more than 200 consumer-product CO deaths a year in the United States, more than 100 linked to portable generators.[4]

Executive summary

  • 7 jurisdictions require CO alarms in existing homes with a CO source without waiting for a sale: 82.2 million people, 24.1 percent of the population in 2025.
  • 9 more states reach existing houses at sale or transfer, adding 37.6 million people (11.0 percent).
  • 5 states reach only rentals or multifamily buildings (6.4 percent of people) and 5 only new homes (15.1 percent).
  • 22 jurisdictions, with 121.9 million people (35.7 percent), had no statewide CO alarm statute or rule we could verify; the adopted IRC section R315 may still apply to new homes there.
  • 82.0 percent of U.S. households had a CO source in 2020, and 67.4 percent of electric-range households still had one (EIA RECS 2020).
  • 62.5 million CO-source households, 61.7 percent, are in jurisdictions with no verified rule for existing owner-occupied houses.
  • A permitted remodel can trigger CO alarms in an existing home under the IRC R315.2.2 text as adopted in Washington and under Colorado and Nebraska statutes.

Questions people ask

Where should carbon monoxide detectors be placed?

Near the bedrooms, and in many codes on every level. Minnesota and Florida set 10 feet from each sleeping room, Colorado 15 feet from each sleeping room entrance, and Washington's IRC text puts alarms outside each sleeping area and on each level. Follow the manufacturer's instructions, which several laws adopt by reference.

Do I need a CO detector if I have an electric stove?

Often yes. In 2020, 67.4 percent of U.S. households with an electric range still burned gas, propane, oil or wood or had an attached garage (EIA RECS 2020), and most state laws key on any of those, not the range alone.

Are landlords required to install CO detectors?

In many states, yes. North Carolina requires 1 alarm per rental unit per level, Montana a detector in each unit, Maryland alarms outside each sleeping area and on every level from April 1, 2018, and Colorado, Massachusetts, Minnesota and Iowa name landlords or rental owners in their laws.

Do I need a CO detector when remodeling?

Often, if the work needs a permit. Under the IRC R315.2.2 text as adopted in Washington, and under Colorado and Nebraska statutes, permitted interior alterations, repairs or additions bring CO alarms into an existing home; Connecticut requires temporary alarms during the work.

Frequently asked questions

How many states require carbon monoxide detectors in existing homes?

By our check of text in force on 2026-11-15, 7 jurisdictions require them in existing homes with a CO source now and 9 states at sale or transfer.

What share of Americans live under a CO alarm law for existing houses?

35.1 percent, or 119.9 million people, using Census Vintage 2025 population.

Which large states have no state CO alarm law verified?

Texas and Ohio are the most populous; the 22 jurisdictions in that group hold 121.9 million people.

Does a CO alarm law apply to an all-electric home?

Usually not, if there is also no fireplace or attached garage. Only 18.0 percent of U.S. households had no combustion fuel and no attached garage in 2020.

When did California require CO detectors?

Existing single-family homes with a CO source by July 1, 2011, other dwelling units by January 1, 2013, and hotel and motel units by January 1, 2017.

What happens if a seller in Oregon skips the CO alarm?

The buyer can sue for the greater of actual damages or $250 per residential unit within 1 year of the sale (ORS 105.840).

How many people die from carbon monoxide each year?

More than 400 Americans a year from unintentional CO poisoning not linked to fires, according to CDC.

Do portable generators cause many CO deaths?

CPSC links more than 100 deaths a year to portable generators and says to run them outside, at least 20 feet from the home.

How many homes use natural gas?

61.0 percent of U.S. households used natural gas in 2020 (EIA RECS 2020).

Does Florida require CO alarms in older homes?

Florida's statute covers buildings and additions built on or after July 1, 2008; existing buildings under alteration or repair are exempt unless the work is an addition.

Download the data

Every table in this report is available as a CSV under CC BY 4.0. The fact sheet lists each value with its source URL and access date.

For journalists and researchers

If you cite only a few, cite these

  1. 35.1 percent (119.9 million) of Americans live under a verified state CO alarm rule for existing houses (KBR registry with Census Vintage 2025).[1]
  2. 61.7 percent of CO-source households sit outside any verified existing-house rule (KBR with EIA RECS 2020).[2]
  3. 82.0 percent of U.S. households have a combustion fuel or attached garage (EIA RECS 2020).[2]

Most quotable statistics

  • 35.1 percent of Americans live where a verified state law reaches existing owner-occupied homes with CO alarm rules, now or at sale (KBR registry, November 2026).[1]
  • 62.5 million U.S. households with a fuel-burning source or attached garage live where no existing-house CO rule was verified.[1][2]
  • 67.4 percent of U.S. homes with an electric range still had a CO source in 2020.[2]
  • 22 jurisdictions with 121.9 million people had no statewide CO alarm law we could verify.[1]
  • More than 400 Americans die each year from unintentional non-fire CO poisoning (CDC).[3]

Press summary

Kitchen and Bath Renovators coded state carbon monoxide alarm laws from statute and rule text in force on November 15, 2026, and sized them with Census 2025 population. 7 jurisdictions require CO alarms in existing homes with a fuel-burning source or attached garage, and 9 more states require them when a house is sold. Together they hold 35.1 percent of Americans, 119.9 million people. 5 states cover only rentals or apartment buildings, 5 cover only new homes, and 22 jurisdictions with 121.9 million people had no state law we could verify. Federal household energy microdata show 82.0 percent of homes have a CO source, including 67.4 percent of homes with an electric range. Overlaying the two, 62.5 million CO-source households sit outside any verified existing-house rule. Remodels matter: a permitted alteration can bring CO alarms into an older home under the IRC text adopted in Washington and statutes in Colorado and Nebraska.

Suggested headlines

  • About a third of Americans live where CO alarm laws reach existing homes
  • 62.5 million homes with a CO source sit outside state alarm rules
  • 22 jurisdictions have no state carbon monoxide alarm law we could verify
  • An electric stove rarely makes a home CO-free, federal microdata show
  • A kitchen remodel permit can bring a carbon monoxide alarm with it

How to cite this report

Kitchen and Bath Renovators. (2026). Carbon Monoxide Detector Requirements by State: Who Must Install, When, and Where. Retrieved from https://kitchenandbathrenovators.com/research/carbon-monoxide-detector-requirements/

Reuse license

Data and tables are licensed CC BY 4.0. Attribution: “Source: Kitchen and Bath Renovators, Carbon Monoxide Detector Requirements by State: Who Must Install, When, and Where” with a link to this page.

Reproduce this analysis

Every figure comes from the files below. The scripts that pulled and computed them are kept with the report and can be re-run.

DatasetPublisherSourceQuery or filterRows usedRetrieved
Vintage 2025 county and state population totals (co-est2025-alldata.csv, shared copy at .tmp/datasets/popest/)U.S. Census BureauFile or endpointSUMLEV = 040, POPESTIMATE202551 state and DC rows2026-11-15
RECS 2020 public use microdata v7 (shared copy at build/kitchenandbathrenovators.com/research_shared/recs2020/)U.S. Energy Information AdministrationFile or endpointUSENG, USELP, USEFO, USEWOOD, PRKGPLC1, RANGEFUEL, FUELHEAT, TYPEHUQ, state_postal; NWEIGHT and NWEIGHT1 to NWEIGHT6018496 household records2026-11-15
State CO alarm statutes and rules (saved in raw/, fetch log raw/_fetch_log.csv)State legislatures and agenciesFile or endpointOne official page per state; passages containing carbon monoxide extracted with scripts/show.py29 jurisdictions coded or flagged; 22 none verified2026-11-15

Data quality and exclusions

  • 3 laws (Alaska, Illinois, Pennsylvania) were named in official records but their operative text did not load after repeated attempts on 2026-11-15; they are flagged as not opened and excluded from coded groups.
  • 4 official pages arrived compressed or as PDFs under an .html name (Oregon, Georgia, Rhode Island, CPSC); they were decoded for reading and the raw bytes kept unchanged.
  • 1 Georgia source is the 2009 revision of the state IRC amendments; later Georgia editions were not opened, so Georgia is coded as new construction only.
  • RECS 2020: all 18496 records used; no records dropped. State estimates are summed to groups.
  • CDC and CPSC figures are rounded lower bounds as published, with no single reference year on those pages.

Methodology

Selection: for each state we opened the official statute, regulation or state code amendment (or a labelled Internet Archive capture of the same official URL when the site did not respond) and saved it in raw/. Secondary lists (NCSL, manufacturers, landlord blogs) were not used as data; NCSL did not load and is listed in excluded.md.

Coding: each jurisdiction gets the strongest residential rule found in its text: existing homes with no trigger, existing homes at sale or transfer, rentals or multifamily only, new construction only, law not opened, or none verified. The candidate list of statutes and the negative searches for the none-verified group started from a compilation by our sister research desk dated 2026-10-27; every coded row was re-opened and read from text saved on 2026-11-15.

Population: Census Vintage 2025 POPESTIMATE2025 at state level (SUMLEV 040) from the shared co-est2025-alldata.csv, summed by group.

Households: EIA RECS 2020 v7 microdata. A CO source is any use of natural gas, propane, fuel oil or wood, or an attached garage. Estimates use NWEIGHT; standard errors use 60 replicate weights with the factor 4/60.

Conflicts: where a state has both a statute and a code amendment, we coded the broader residential reach and cite both. We did not infer coverage for laws whose text we could not open.

Limitations: adopted building codes (IRC R315) and local ordinances are not coded, so group E is not a statement that new homes there lack CO alarms. RECS 2020 households are overlaid on 2026 law.

Last update: 2026-11-15. The registry is rechecked each quarter.

This report presents published data with its limitations. It is not legal, financial or investment advice.

Sources, ranked by quality