Aluminum Wiring: The 1965 to 1973 Homes, State by State
- Primary data
- Census ACS 2025 1-year B25034 with Census New Residential Construction starts by region
- Data period
- Homes standing in 2025, built 1965 to 1973
- Latest release used
- 2026-10-29
- Next release
- ACS 2026 1-year, expected autumn 2027
- Geography
- United States, 50 states and DC
- Sources
- 26 (24 Tier 1)
An estimated 15.8 million US homes standing in 2025 were built from 1965 to 1973, the window when builders used aluminum wiring in branch circuits after a copper shortage. CPSC reports pre-1972 aluminum-wired homes were 55 times more likely to have outlet connections reach fire hazard conditions, and accepts only copper rewiring, COPALUM or AlumiConn as permanent repairs.
Aluminum wiring entered homes on a copper shortage and lost favor with a 1972 alloy change
Federal and industry records place aluminum branch wiring in a short window. CPSC says homes built before 1965 are unlikely to have it, and USGS price data show copper climbing 79.5% from 1964 to 1970 while aluminum barely moved.
The U.S. Consumer Product Safety Commission (Publication 516, June 2011) says a copper shortage in the mid 1960s pushed builders to run aluminum wire on general purpose 15 and 20 amp circuits, not only on the large dryer and range circuits where it was already common. CPSC adds that homes built before 1965 are unlikely to have aluminum branch circuit wiring, and that cables installed from 1965 to the mid 1970s, in new homes, additions and rewired circuits, may contain it.
USGS historical statistics show the price gap that made the switch attractive. The US copper unit value rose from $713 a metric ton in 1964 to $1,280 in 1970, while aluminum went from $522 to $633 (USGS copper statistics; USGS aluminum statistics). Copper cost 1.37 times as much as aluminum per ton in 1964, 2.02 times in 1970 and 2.25 times in 1973. US copper stocks fell from 1,200,000 metric tons in 1960 to 342,000 in 1969, a 71.5% drop.
US unit value, dollars per metric ton, 1960 to 1979
Source: USGS Data Series 140, copper and aluminum statistics
The window closed through product standards rather than a ban. NEMA (2012 white paper) dates the industry reevaluation program to 1970 and says that by mid-1972 only requalified aluminum conductors and CO/ALR wiring devices were acceptable under industry standards. IAEI (January/February 2006) says AA-8000 series alloy wire was listed and manufactured beginning in 1972. The National Electrical Code first named AA-8000 conductors specifically in its 1987 edition.
Branch circuit aluminum wiring: Solid aluminum conductors, sized No. 10 and No. 12 AWG, feeding outlets, switches and fixtures on 15 and 20 amp circuits. CPSC's repair guidance does not cover the larger aluminum service entrance, dryer and range cables, or copper-clad aluminum wire.
CPSC's 55-times finding covers outlets in homes built before 1972
The most cited federal number comes from a Franklin Research Institute survey done for CPSC. It measures outlet connections only, and it stops at 1972.
CPSC reports that the national Franklin Research Institute survey found homes built before 1972 and wired with aluminum were 55 times more likely than copper-wired homes to have one or more outlet connections reach Fire Hazard Conditions (CPSC Publication 516). The survey defined that condition as a receptacle cover plate screw reaching 149 degrees C (300 degrees F), sparks from the receptacle, or charring of nearby materials.
- The survey covered wire connections at outlets only; CPSC notes that other aluminum connections and splices are also prone to fail.
- CPSC says no information was developed for aluminum-wired homes built after 1972.
- On April 28, 1974, two people died in a Hampton Bays, New York, house fire that fire officials traced to an overheating aluminum connection at a wall receptacle, according to CPSC.
- CPSC says failing aluminum connections seldom give warning signs; the signs it lists are hot face plates, flickering lights, dead circuits and a burning plastic smell.
Laboratory work at the National Bureau of Standards (Journal of Research, 1980) explains the mechanism. In a loose connection, arcing at the iron screw and aluminum wire interface produced temperatures in excess of 1,500 degrees C and formed intermetallic compounds with high resistivity. A tight receptacle connection carrying 15 amps dissipates on the order of 80 milliwatts; a glowing connection has been reported at up to 36 watts.
15.8 million surviving homes date from the 1965 to 1973 window
Splitting the Census 2025 decade counts by the timing of regional housing starts puts 15.8 million homes, 10.7% of all US housing units, in the 1965 to 1973 build years. This is an era estimate, not a count of homes that have aluminum wiring.
The 2025 American Community Survey counts 14.0 million housing units built from 1960 to 1969 and 20.1 million built from 1970 to 1979 (ACS 2025 1-year, B25034). Census does not publish single years, so KBR weighted each decade by the share of that decade's private housing starts that fell inside the window, region by region (Census New Residential Construction). Nationally, 1965 to 1969 held 0.491 of 1960s starts and 1970 to 1973 held 0.446 of 1970s starts.
Estimated, percent of all housing units, 2025
Source: KBR estimate from Census ACS 2025 1-year B25034 and Census regional housing starts
California has the most era homes, an estimated 1.8 million, followed by Texas (1.2 million), Florida (1.1 million), New York (917,223) and Illinois (643,887). Those five states hold 35.8% of the national estimate.
Estimated housing units, thousands, 2025
Source: KBR estimate from Census ACS 2025 1-year B25034 and Census regional housing starts
Show all 51 rows
| State | Code | Census region | Built 1960 to 1969 (ACS) | Built 1970 to 1979 (ACS) | Est. built 1965 to 1973 | MOE (90%) | Share of housing (%) | Rank by count | Rank by share | Owner-occupied est. |
|---|---|---|---|---|---|---|---|---|---|---|
| California | CA | West | 1812566 | 2438722 | 1765484 | 15926 | 11.77 | 1 | 15 | 878685 |
| Texas | TX | South | 916658 | 1554181 | 1199640 | 15753 | 9.34 | 2 | 40 | 654661 |
| Florida | FL | South | 810653 | 1563114 | 1149072 | 14423 | 10.65 | 3 | 27 | 640775 |
| New York | NY | Northeast | 1033673 | 851381 | 917223 | 12411 | 10.5 | 4 | 29 | 478141 |
| Illinois | IL | Midwest | 612562 | 774667 | 643887 | 11284 | 11.7 | 5 | 16 | 401952 |
| Pennsylvania | PA | Northeast | 577678 | 714468 | 632322 | 9661 | 10.75 | 6 | 26 | 384572 |
| Ohio | OH | Midwest | 601557 | 737493 | 622684 | 10512 | 11.6 | 7 | 17 | 377556 |
| Michigan | MI | Midwest | 540267 | 684413 | 568381 | 8059 | 12.11 | 8 | 8 | 361316 |
| North Carolina | NC | South | 392202 | 582009 | 474510 | 8789 | 9.18 | 9 | 43 | 272417 |
| New Jersey | NJ | Northeast | 485150 | 449829 | 455695 | 9089 | 11.91 | 10 | 13 | 274822 |
| Virginia | VA | South | 361441 | 531735 | 435132 | 8408 | 11.51 | 11 | 18 | 266148 |
| Georgia | GA | South | 330654 | 535067 | 420790 | 8361 | 8.89 | 12 | 46 | 234728 |
| Tennessee | TN | South | 310710 | 442298 | 367140 | 8963 | 11.16 | 13 | 20 | 212401 |
| Missouri | MO | Midwest | 302706 | 396867 | 324008 | 6558 | 11.27 | 14 | 19 | 201726 |
| Indiana | IN | Midwest | 303971 | 386131 | 320227 | 6926 | 10.49 | 15 | 30 | 203987 |
| Washington | WA | West | 281122 | 476291 | 314105 | 7285 | 9.14 | 16 | 44 | 179561 |
| Maryland | MD | South | 301068 | 339180 | 313974 | 8250 | 12.01 | 17 | 10 | 177820 |
| Massachusetts | MA | Northeast | 295158 | 332112 | 306555 | 7601 | 9.98 | 18 | 36 | 177153 |
| Wisconsin | WI | Midwest | 272817 | 389823 | 305332 | 6442 | 10.76 | 19 | 25 | 183396 |
| Alabama | AL | South | 248068 | 343634 | 288685 | 7069 | 12.0 | 20 | 11 | 166664 |
| Louisiana | LA | South | 223884 | 368430 | 287783 | 8147 | 13.34 | 21 | 2 | 164181 |
| Arizona | AZ | West | 205437 | 467694 | 278691 | 6216 | 8.26 | 22 | 48 | 163599 |
| Minnesota | MN | Midwest | 226997 | 358850 | 268343 | 6118 | 10.26 | 23 | 35 | 169012 |
| Kentucky | KY | South | 204577 | 309357 | 250208 | 6115 | 12.09 | 24 | 9 | 149478 |
| Colorado | CO | West | 189886 | 408011 | 247619 | 5881 | 9.2 | 25 | 42 | 150853 |
| Oklahoma | OK | South | 188862 | 309884 | 242339 | 5134 | 13.34 | 26 | 3 | 132435 |
| South Carolina | SC | South | 189754 | 305581 | 240789 | 6676 | 9.33 | 27 | 41 | 144621 |
| Connecticut | CT | Northeast | 203995 | 202959 | 198540 | 5573 | 12.74 | 28 | 4 | 126466 |
| Oregon | OR | West | 159220 | 318249 | 197823 | 5291 | 10.36 | 29 | 33 | 114480 |
| Mississippi | MS | South | 145458 | 209943 | 173222 | 5944 | 12.65 | 30 | 5 | 103595 |
| Arkansas | AR | South | 130533 | 220501 | 170449 | 5292 | 11.87 | 31 | 14 | 102342 |
| Iowa | IA | Midwest | 139028 | 191856 | 152781 | 4078 | 10.41 | 32 | 32 | 99673 |
| Kansas | KS | Midwest | 118360 | 185824 | 139385 | 3772 | 10.57 | 33 | 28 | 83151 |
| West Virginia | WV | South | 80312 | 134323 | 104243 | 4046 | 11.96 | 34 | 12 | 64734 |
| New Mexico | NM | West | 82176 | 165974 | 102806 | 3881 | 10.47 | 35 | 31 | 59693 |
| Utah | UT | West | 70137 | 171803 | 100130 | 3285 | 7.66 | 36 | 49 | 63235 |
| Nebraska | NE | Midwest | 92543 | 117257 | 97368 | 3138 | 10.93 | 37 | 22 | 60345 |
| Nevada | NV | West | 65995 | 152400 | 90413 | 3623 | 6.53 | 38 | 51 | 45207 |
| Hawaii | HI | West | 79624 | 122506 | 83873 | 3095 | 14.6 | 39 | 1 | 44038 |
| Maine | ME | Northeast | 50692 | 103437 | 75924 | 3308 | 9.84 | 40 | 37 | 45317 |
| Idaho | ID | West | 45834 | 127880 | 71847 | 2866 | 8.46 | 41 | 47 | 45657 |
| New Hampshire | NH | Northeast | 50518 | 94805 | 71512 | 3654 | 10.8 | 42 | 24 | 44427 |
| Rhode Island | RI | Northeast | 55823 | 66490 | 59824 | 3442 | 12.23 | 43 | 7 | 33822 |
| Montana | MT | West | 38266 | 81601 | 49645 | 2328 | 9.12 | 44 | 45 | 30477 |
| Delaware | DE | South | 40655 | 52432 | 45496 | 2931 | 9.41 | 45 | 39 | 28534 |
| South Dakota | SD | Midwest | 33119 | 55819 | 40586 | 2415 | 9.45 | 46 | 38 | 23546 |
| Alaska | AK | West | 24015 | 74114 | 40566 | 2109 | 12.27 | 47 | 6 | 22177 |
| North Dakota | ND | Midwest | 28148 | 60138 | 39754 | 2073 | 10.35 | 48 | 34 | 25364 |
| Vermont | VT | Northeast | 26875 | 49184 | 37416 | 2115 | 10.81 | 49 | 23 | 22994 |
| Wyoming | WY | West | 20563 | 54998 | 31258 | 2025 | 11.02 | 50 | 21 | 19079 |
| District of Columbia | DC | South | 31883 | 19770 | 25703 | 2517 | 6.92 | 51 | 50 | 6821 |
Era estimate, not homes with aluminum wiring. MOE covers ACS sampling error only. Estimate = 1960s weight x built 1960 to 1969 + 1970s weight x built 1970 to 1979, weights from regional private starts (table t2).
Source: [1][2][5] U.S. Census Bureau; U.S. Census Bureau; U.S. Census Bureau
Among owner-occupied homes, the estimate is 9.1 million, or 10.42% of owner-occupied units (ACS B25036). Of occupied homes built from 1960 to 1979, 68.0% are in one-unit structures and 4.42% are mobile homes, boats, RVs or vans (ACS B25127).
The window holds three of the four biggest years for US housing starts
The aluminum years were also boom years. Private starts reached a record 2.36 million in 1972, so the 1970s weight leans toward the window's end.
Census annual starts, a series that begins in 1959, peak at 2,357 thousand units in 1972. The next three years are 2005 (2,068 thousand), 1971 (2,052 thousand) and 1973 (2,045 thousand), so 3 of the four highest years fall inside the 1965 to 1973 window (Census starts by region). Private starts across the nine window years total 14,791 thousand units.
US private housing starts, thousands, 1960 to 1979
Source: Census Bureau, New Residential Construction, annual starts
| Region | Starts 1965 to 1969 (000) | Starts 1960 to 1969 (000) | 1960s weight | Starts 1970 to 1973 (000) | Starts 1970 to 1979 (000) | 1970s weight | 1970s weight, completions |
|---|---|---|---|---|---|---|---|
| Northeast | 1124.5 | 2371.5 | 0.474 | 1088.5 | 2169.9 | 0.502 | 0.465 |
| Midwest | 1704.2 | 3232.4 | 0.527 | 1610.1 | 3886.5 | 0.414 | 0.401 |
| South | 2773.6 | 5370.9 | 0.516 | 3436.7 | 7354.4 | 0.467 | 0.438 |
| West | 1301.2 | 3088.9 | 0.421 | 1752.3 | 4265.1 | 0.411 | 0.401 |
| United States | 6903.7 | 14063.8 | 0.491 | 7887.7 | 17675.8 | 0.446 | 0.424 |
Private starts, thousands of units. Completions by region begin in 1968, so they serve only as a check on the 1970s weight.
The Northeast's 1970s weight (0.502) is the highest of the four regions because its building fell off after 1973; the Midwest's (0.414) is the lowest because its starts stayed strong through 1978.
CPSC accepts three permanent repairs and calls CO/ALR devices an incomplete fix
CPSC's 2011 guidance names one replacement method and two pigtail connectors as permanent. Twist-on pigtails and CO/ALR devices are, in CPSC staff's view, temporary at best.
The Commission voted unanimously, 5 to 0, on a ballot due March 21, 2011, to republish Publication 516 with explicit recognition that COPALUM and AlumiConn connectors were the only products meeting the agency's standards (CPSC Record of Commission Action). The publication sets three tests: a repair must be safe, effective and permanent.
| Method | CPSC position | CPSC note | Date of guidance |
|---|---|---|---|
| Complete replacement with copper cable | Permanent; CPSC calls it the best method | Removes the aluminum wire as the cause; often impractical or prohibitively expensive | June 2011 |
| COPALUM crimp connector pigtail | Permanent; recommended | Power tool, upwards of 10,000 pounds of force; manufacturer-trained electricians only | June 2011 |
| AlumiConn setscrew connector pigtail | Permanent; acceptable alternative where COPALUM is unavailable | Performed well in initial tests; too new for a long-term history as of 2011 | June 2011 |
| Other (non-COPALUM) crimp connectors | Recommended against | No other crimp connectors evaluated for copper to aluminum | June 2011 |
| Twist-on connector pigtails | Not a permanent repair; emergency or temporary only | Substantial numbers overheated severely in CPSC-sponsored tests | June 2011 |
| CO/ALR switches and receptacles | Incomplete repair at best; emergency or temporary only | Failed lab tests with typical installed aluminum wire; not made for all parts of the system | June 2011 |
Paraphrased from CPSC Publication 516 (June 2011). CPSC says all repairs should be done by a qualified electrician and inspected under local rules.
Source: [7][8] U.S. Consumer Product Safety Commission; U.S. Consumer Product Safety Commission
CPSC calls full copper replacement the best method but says it is impractical or prohibitively expensive in many homes. COPALUM uses a dedicated power tool whose dies apply upwards of 10,000 pounds of force, and only manufacturer-trained electricians may install it. CPSC describes AlumiConn, a setscrew connector, as the next best alternative when COPALUM is not available.

Four of nine Maine insurer filings name aluminum wiring; Texas and Louisiana sale forms ask about it
Insurer rules range from outright ineligibility to acceptance with an electrician's certificate. Two of three state sale disclosure forms we checked name aluminum wiring.
Of nine homeowners underwriting guideline files posted by the Maine Bureau of Insurance, four name aluminum wiring (4 of 9 (44.4%)). Hanover (2018) and both Integon National files (2019; undated) list it as making a home ineligible. State Farm (effective 2023) excludes single strand aluminum wiring unless a licensed electrician certifies that every connection was repaired with methods approved by CPSC.
In Florida, the Citizens Property Insurance 4-point inspection form (Insp4pt 01 18) asks the inspector to flag branch circuit aluminum wiring and to say whether connections were repaired with a COPALUM crimp or AlumiConn, with remediation certified by a licensed electrician.
| Body | Document type | Position | Date |
|---|---|---|---|
| Citizens Property Insurance (FL) | Insurer inspection form | Flags branch circuit aluminum wiring; asks for COPALUM or AlumiConn repair records certified by an electrician | Form 01 18 |
| State Farm (ME filing) | Insurer guideline | Unacceptable unless an electrician certifies all connections repaired by CPSC-approved methods | 2023-01-01 |
| Hanover (ME filing) | Insurer guideline | Aluminum and knob and tube wiring listed as ineligible risks | 2018-12-03 |
| Integon National OneChoice (ME) | Insurer guideline | Ineligible when knob and tube or aluminum wiring is present | 2019-04-25 |
| Integon National OneChoice and Premier (ME) | Insurer guideline | Ineligible when knob and tube or aluminum wiring is present | Undated |
| Five other Maine filings | Insurer guideline | Do not name aluminum wiring | 2007 to 2023 editions |
| Texas Real Estate Commission | Seller disclosure form | Aluminum Wiring listed among conditions the seller must answer | 2026-05-28 |
| Louisiana Real Estate Commission | Seller disclosure form | Question 20c asks about any aluminum wiring in the structure | 2026-01 |
| Washington (RCW 64.06.020) | Statutory disclosure form | Asks about electrical defects, including wiring; does not name aluminum | Current |
Maine files are insurer filings posted by the Maine Bureau of Insurance, read through Internet Archive captures; they may have been superseded.
Source: [12][13][14][15][16][17][18][19][20][21][22][23][24] Citizens Property Insurance Corporation (Florida); State Farm via Maine Bureau of Insurance (Internet Archive); Hanover Insurance Group via Maine Bureau of Insurance (Internet Archive); Integon National via Maine Bureau of Insurance (Internet Archive); Integon National via Maine Bureau of Insurance (Internet Archive); Farmers via Maine Bureau of Insurance (Internet Archive); Farmers via Maine Bureau of Insurance (Internet Archive); USAA via Maine Bureau of Insurance (Internet Archive); Chubb via Maine Bureau of Insurance (Internet Archive); Unnamed insurer via Maine Bureau of Insurance (Internet Archive); Texas Real Estate Commission; Louisiana Real Estate Commission; Washington State Legislature
Texas's seller's disclosure notice, effective May 28, 2026, lists Aluminum Wiring among the conditions a seller must say whether they are aware of (TREC No. 55-1). Louisiana's January 2026 property disclosure document asks: Are you aware of any aluminum wiring in the structure? (LREC). Washington's statutory form asks about defects in the electrical system, including wiring, without naming aluminum (RCW 64.06.020). Texas and Louisiana together hold an estimated 1,487,423 era homes.
Ending the window in 1972 or 1975 moves the count by 2.3 to 2.8 million homes
The weights matter less than the window. Swapping starts for completions changes the total by 2.8% and one national weight pair by 0.1%; ending the window in 1972 or 1975 changes it by 14.7% or 17.9%.
| Variant | Estimated homes | Share of US housing (%) |
|---|---|---|
| Main estimate: 1965 to 1973, regional starts weights | 15841182 | 10.69 |
| 1965 to 1973, one national weight pair | 15852003 | 10.69 |
| 1965 to 1973, completions for the 1970s | 15396349 | 10.39 |
| 1965 to 1973, mobile-home share removed | 15140550 | 10.21 |
| Narrower: 1965 to 1972 | 13518928 | 9.12 |
| Wider: 1965 to 1975 | 18684512 | 12.61 |
All variants use ACS 2025 1-year decade counts for 50 states and DC.
Source: [1][3][5][6] U.S. Census Bureau; U.S. Census Bureau; U.S. Census Bureau; U.S. Census Bureau
Estimated US homes, millions, 2025
Source: KBR estimates from Census ACS 2025 1-year and Census starts and completions
The main estimate is 1.07 times the private starts recorded for 1965 to 1973. A ratio above 1 is a warning sign: the ACS counts mobile homes and public housing that private starts omit, and households tend to round year built to a decade. Removing the mobile-home share cuts the ratio to 1.02. Read 15.8 million as an upper-leaning era figure.
Dishwashers, light fixtures and junction boxes are on CPSC's repair list too
CPSC's repair scope reaches beyond outlets and switches to permanently connected appliances, which is where kitchen and bathroom projects meet the old wiring.
CPSC says every aluminum connection or splice should be repaired, including outlets, dimmers, switches, fixtures, appliances and junction boxes, and names dishwashers, heaters, air conditioners and light fixtures wired directly to No. 10 or No. 12 aluminum circuits. CPSC also says all modifications to installed wiring should be performed and inspected under local rules.
For a homeowner planning a remodel in a 1965 to 1973 house, those points mean the electrical scope and permit can affect schedule; our kitchen remodel timeline and guide to choosing a remodeling contractor cover how to plan those steps. Related old-house hazards are covered in our reports on knob and tube wiring, Federal Pacific panels, polybutylene pipe and Chinese drywall.

Dated official positions on aluminum branch wiring
Checked at each report refresh (planned yearly with the ACS 1-year release). Last checked 2026-11-08. Entries are neutral records of public data; each links to its source record.
| Body | Position or action | Date | Evidence | Source |
|---|---|---|---|---|
| U.S. Consumer Product Safety Commission | Commission votes 5 to 0 to republish Publication 516 naming COPALUM and AlumiConn as the only products meeting its standards | 2011-03-21 | agency record | Record |
| U.S. Consumer Product Safety Commission | Publication 516 approves three permanent repairs: copper replacement, COPALUM, AlumiConn | 2011-06 | agency record | Record |
| U.S. Consumer Product Safety Commission | Publication 516 rejects twist-on pigtails and CO/ALR devices as permanent repairs | 2011-06 | agency record | Record |
| Citizens Property Insurance Corporation | 4-point form asks for aluminum branch wiring and COPALUM or AlumiConn remediation records | Form 01 18 | own statement | Record |
| State Farm (Maine filing) | Single strand aluminum wiring unacceptable unless repaired by CPSC-approved methods and certified | 2023-01-01 | own statement | Record |
| Hanover (Maine filing) | Aluminum wiring listed among home ineligible risks | 2018-12-03 | own statement | Record |
| Integon National (Maine filing) | Homes with aluminum wiring present are ineligible | 2019-04-25 | own statement | Record |
| Integon National, Premier Client (Maine filing) | Homes with aluminum wiring present are ineligible | Undated | own statement | Record |
| Texas Real Estate Commission | Seller's Disclosure Notice 55-1 lists Aluminum Wiring | 2026-05-28 | agency record | Record |
| Louisiana Real Estate Commission | Property Disclosure Document question 20c asks about aluminum wiring | 2026-01 | agency record | Record |
State-by-state findings
- An estimated 15.8 million US housing units built 1965 to 1973 were standing in 2025, 10.7% of 148.2 million units.[1][5]
- Owner-occupied era homes number an estimated 9.1 million, 10.42% of US owner-occupied units in 2025.[2][5]
- California leads by count with an estimated 1,765,484 era homes in 2025, followed by Texas (1,199,640) and Florida (1,149,072).[1][5]
- Hawaii has the highest era share in 2025 at 14.6%; Louisiana and Oklahoma follow at 13.34%.[1][5]
- Nevada has the lowest era share in 2025 at 6.53%, then DC (6.92%) and Utah (7.66%).[1][5]
- Five states, California, Texas, Florida, New York and Illinois, hold 35.8% of the US era estimate.[1][5]
- US private housing starts hit a record 2,356.6 thousand in 1972; 3 of the 4 highest years since 1959 fall in 1965 to 1973.[5]
- CPSC: homes built before 1972 with aluminum wiring were 55 times more likely to have outlet connections reach Fire Hazard Conditions than copper-wired homes.[7]
- CPSC defines Fire Hazard Conditions as a cover plate screw at 149 degrees C (300 degrees F), sparks, or charring.[7]
- National Bureau of Standards tests in 1980 found arcing temperatures above 1,500 degrees C at loose iron screw and aluminum wire interfaces.[9]
- The CPSC Commission voted 5 to 0 in March 2011 to republish Publication 516 recognizing only COPALUM and AlumiConn connectors.[8]
- US copper unit value rose 79.5% from 1964 to 1970, while US copper stocks fell 71.5% from 1960 to 1969.[10]
- State Farm's 2023 Maine guidelines accept solid aluminum wiring only with an electrician's certificate of CPSC-approved repairs.[13]
- Texas (May 2026) and Louisiana (January 2026) seller disclosure forms ask about aluminum wiring by name; Washington's does not.[22][23][24]
Rankings and ratios we derived
Homes built 1965 to 1973, by state (signature estimate)
Formulaera[state] = w60[region] x B25034 built 1960 to 1969 + w70[region] x B25034 built 1970 to 1979; w60 = private starts 1965 to 1969 / starts 1960 to 1969; w70 = starts 1970 to 1973 / starts 1970 to 1979; US = sum of 50 states and DC
Inputs: fact rows 2, 3, 9 to 13; tables t1 and t2 (fact sheet rows)
Result: 15,841,182 homes (10.69% of US housing units); MOE about 43,352 from ACS sampling
The number of homes that date from the years CPSC ties to aluminum branch wiring. It sizes exposure to the era, which is the most a public dataset can show.
Limitations: Not homes with aluminum wiring; no federal survey asks about wire metal. Assumes surviving homes are spread within each decade like regional starts were. Hawaii and Alaska get West region weights.
State share ranking
Formulashare[state] = era[state] / B25034 total units; ranked 1 to 51
Inputs: table t1 (fact sheet rows)
Result: Highest Hawaii 14.6%, lowest Nevada 6.53%
Shares show where era homes make up more of the local stock, which matters for local inspectors and insurers.
Limitations: State margins of error are small relative to the method uncertainty in table t6.
Copper to aluminum price ratio
FormulaUSGS copper unit value / USGS aluminum unit value, by year
Inputs: fact rows 38 to 47; table t5 (fact sheet rows)
Result: 1.37 in 1964, 2.02 in 1970, 2.25 in 1973
The widening gap matches CPSC's account of a mid 1960s copper shortage driving the switch.
Limitations: Unit values of metal, not wire or installed cost.
Check against private starts
Formulad1 / starts 1965 to 1973; repeated after removing the mobile-home share of occupied 1960 to 1979 homes
Inputs: derived d1, d10, d13 (fact sheet rows)
Result: 1.07 (all units), 1.02 (mobile homes removed)
Survivors cannot exceed homes built, so a ratio above 1 shows the estimate leans high.
Limitations: Starts exclude public housing; ACS year built is self-reported.
Sensitivity to window and weights
FormulaRecompute d1 with completions weights, one national weight pair, 1965 to 1972 and 1965 to 1975 windows
Inputs: table t6 (fact sheet rows)
Result: 13.5 million to 18.7 million
Where the window ends matters far more than how the decades are split.
Limitations: CPSC itself gives two bounds: before 1972 for its survey, and the mid 1970s for installation.
Executive summary
- KBR estimates 15.8 million US housing units standing in 2025 were built from 1965 to 1973, 10.7% of the stock; the figure marks the aluminum wiring era, not homes confirmed to have it.
- California has the most era homes (1.8 million); Hawaii has the highest share (14.6%) and Nevada the lowest (6.53%).
- CPSC reports that pre-1972 aluminum-wired homes were 55 times more likely than copper-wired homes to have outlet connections reach Fire Hazard Conditions.
- CPSC accepts three permanent repairs: copper rewiring, COPALUM crimps and AlumiConn connectors; it treats twist-on pigtails and CO/ALR devices as temporary.
- Copper cost 1.37 times as much as aluminum per ton in 1964 and 2.02 times in 1970, per USGS unit values.
- Four of nine Maine insurer guideline files name aluminum wiring; Texas and Louisiana seller disclosure forms ask about it by name.
- Ending the window in 1972 or 1975 instead of 1973 moves the estimate to 13.5 million or 18.7 million.
Questions people ask
Is aluminum wiring dangerous?
CPSC reports that pre-1972 aluminum-wired homes were 55 times more likely than copper-wired homes to have at least one outlet connection reach Fire Hazard Conditions, and it links an April 1974 house fire that killed two people to an overheating aluminum connection. The risk sits at connections and splices, not along the wire.
How do I know if my house has aluminum wiring?
CPSC says to look at the cable jacket where it is visible in an unfinished basement, attic or garage for the marking Al or Aluminum; Cu-clad or Copper-clad marks copper-coated aluminum, which its repair guidance does not cover. Homes built before 1965 are unlikely to have it. If the marking cannot be read, CPSC says to have a qualified electrician check.
Can you get insurance with aluminum wiring?
Practices differ by insurer. Four of nine Maine guideline files name aluminum wiring: Hanover and two Integon National files list it as ineligible, while State Farm accepts it with an electrician's certificate of CPSC-approved repairs. Florida's Citizens form asks for COPALUM or AlumiConn repair records.
What does pigtailing cost?
We found no government or other primary source that publishes a price for pigtailing aluminum wiring, so we report none. CPSC says only that copper rewiring is often prohibitively expensive and that twist-on and CO/ALR fixes are favored by some electricians because they cost substantially less than COPALUM.
When did they stop using aluminum wiring?
There was no single end date. NEMA says that by mid-1972 only requalified aluminum conductors and CO/ALR devices met industry standards, and CPSC says cables installed through the mid 1970s may contain aluminum. The NEC first named AA-8000 alloy conductors in its 1987 edition.
Download the data
Every table in this report is available as a CSV under CC BY 4.0. The fact sheet lists each value with its source URL and access date.
For journalists and researchers
If you cite only a few, cite these
- 15.8 million US homes date from the 1965 to 1973 aluminum wiring era (KBR estimate, ACS 2025).[1][5]
- CPSC: 55 times more likely to reach Fire Hazard Conditions at outlets, pre-1972 aluminum vs copper.[7]
- California holds the most era homes (1.8 million); Hawaii the highest share (14.6%).[1][5]
Most quotable statistics
- An estimated 15.8 million US homes standing in 2025 were built from 1965 to 1973, the aluminum branch wiring era (10.7% of housing units).[1][5]
- Pre-1972 aluminum-wired homes were 55 times more likely than copper-wired homes to have outlet connections reach Fire Hazard Conditions, per a CPSC-sponsored survey.[7]
- Hawaii has the highest share of housing from the aluminum wiring years, an estimated 14.6% in 2025; Nevada has the lowest, 6.53%.[1][5]
- CPSC recognizes only copper rewiring, COPALUM crimps and AlumiConn connectors as permanent aluminum wiring repairs.[7][8]
- Copper cost 2.02 times as much as aluminum per ton in 1970, up from 1.37 in 1964, according to USGS unit values.[10][11]
- Four of nine homeowners guideline files filed in Maine name aluminum wiring; three make such homes ineligible.[13][14][15][16]
Press summary
Kitchen and Bath Renovators estimates that 15.8 million US homes standing in 2025 were built from 1965 to 1973, the years when builders wired outlets and switches with solid aluminum during a copper shortage. That is 10.7% of the nation's 148.2 million housing units, according to an analysis of Census American Community Survey 2025 data weighted by regional housing starts. California has the most era homes, about 1.8 million, and Hawaii the highest share, 14.6%. The estimate counts homes from the era, not homes confirmed to have aluminum wiring. The U.S. Consumer Product Safety Commission reports that pre-1972 aluminum-wired homes were 55 times more likely than copper-wired homes to have outlet connections reach fire hazard conditions, and it accepts only three permanent repairs: copper rewiring, COPALUM crimps and AlumiConn connectors. Four of nine insurer guideline files filed in Maine name aluminum wiring, and Texas and Louisiana seller disclosure forms ask about it.
Suggested headlines
- 15.8 million US homes date from the aluminum wiring years
- Hawaii, Louisiana and Oklahoma lead in homes from the aluminum wiring era
- CPSC still recognizes only three permanent fixes for aluminum wiring
- Copper cost 2.02 times as much as aluminum when builders switched wire
- Texas and Louisiana sale forms ask about aluminum wiring; Washington's does not
How to cite this report
Kitchen and Bath Renovators. (2026). Aluminum Wiring: The 1965 to 1973 Homes, State by State. Retrieved from https://kitchenandbathrenovators.com/research/aluminum-wiring/
Reuse license
Data and tables are licensed CC BY 4.0. Attribution: “Source: Kitchen and Bath Renovators, Aluminum Wiring: The 1965 to 1973 Homes, State by State” with a link to this page.
Frequently asked questions
How many US homes were built during the aluminum wiring years?
KBR estimates 15.8 million homes standing in 2025 were built from 1965 to 1973, 10.7% of US housing units, from ACS 2025 1-year data and Census housing starts.
Which state has the most homes from that era?
California, with an estimated 1,765,484 homes built 1965 to 1973, followed by Texas with 1,199,640.
Which state has the highest share of era homes?
Hawaii, at an estimated 14.6% of its housing units in 2025. Nevada has the lowest share at 6.53%.
What did the Franklin Research Institute study find?
In a national survey done for CPSC, homes built before 1972 and wired with aluminum were 55 times more likely than copper-wired homes to have one or more outlet connections reach Fire Hazard Conditions.
What counts as a Fire Hazard Condition in that study?
A receptacle cover plate screw reaching 149 degrees C (300 degrees F), sparks emitted from the receptacle, or charred material around it, per CPSC Publication 516.
Which aluminum wiring repairs does CPSC accept as permanent?
Three: complete replacement with copper, pigtailing with COPALUM crimp connectors, and pigtailing with AlumiConn connectors where COPALUM is unavailable.
Are CO/ALR outlets enough?
CPSC staff call CO/ALR devices, at best, an incomplete repair, because they failed lab tests with typical installed aluminum wire and are not made for every part of the system.
Are purple twist-on connectors a permanent fix?
CPSC does not treat any twist-on connector pigtail as a permanent repair; it says substantial numbers of twist-on connectors overheated severely in CPSC-sponsored tests and allows them only as an emergency, temporary repair.
Why did builders use aluminum wire?
CPSC cites a copper shortage in the mid 1960s. USGS data show copper cost 1.37 times as much as aluminum per ton in 1964 and 2.02 times in 1970.
Do home sellers have to disclose aluminum wiring?
It depends on the state. Texas's TREC 55-1 notice and Louisiana's 2026 property disclosure document name aluminum wiring; Washington's statutory form asks only about electrical defects. This is not legal advice.
Reproduce this analysis
Every figure comes from the files below. The scripts that pulled and computed them are kept with the report and can be re-run.
| Dataset | Publisher | Source | Query or filter | Rows used | Retrieved |
|---|---|---|---|---|---|
| ACS 2025 1-year table-based Summary File, B25034, B25036 | U.S. Census Bureau | File or endpoint | Shared copy read in place at .tmp/datasets/acs/2025_1yr/; GEO_ID 0100000US and 0400000US (SUMLEVEL 040, COMPONENT 00 via Geos20251YR.txt), Puerto Rico dropped; B25034_E001, E007, E008 and MOEs; B25036_E002, E008, E009 | 52 rows (US, 50 states, DC) | 2026-11-08 |
| ACS 2025 1-year table-based Summary File, B25127 | U.S. Census Bureau | File or endpoint | Lines 024, 025, 030 (owner) and 067, 068, 073 (renter): built 1960 to 1979 total, one-unit, mobile home | US row used; 50 of 51 state rows present (Wyoming not published) | 2026-11-08 |
| New Residential Construction, annual housing units started by region | U.S. Census Bureau | File or endpoint | Sheet Annual; Total columns for US, Northeast, Midwest, South, West; 1960 to 1979 for weights, 1959 to 2025 for ranks | 20 years x 5 geographies for weights; 67 annual US rows for ranking | 2026-11-08 |
| New Residential Construction, annual housing units completed by region | U.S. Census Bureau | File or endpoint | Sheet Annual; Total columns; 1970 to 1979 | 10 years x 5 geographies | 2026-11-08 |
| Historical Statistics for Mineral and Material Commodities, copper and aluminum (Data Series 140) | U.S. Geological Survey | File or endpoint | Unit value ($/t) and stocks columns, 1960 to 1979; aluminum file ds140-aluminum-2021.xlsx unit value column | 20 years per metal | 2026-11-08 |
| Maine homeowners underwriting guidelines, nine insurer files (Internet Archive captures of maine.gov) | Maine Bureau of Insurance via Internet Archive | File or endpoint | Full text extracted with pdftotext and searched for 'aluminum'; other eight file URLs are sources s14 to s21 | 9 files; 4 with an aluminum wiring rule | 2026-11-08 |
Data quality and exclusions
- Puerto Rico removed from the ACS state rows (1 row); the analysis covers 50 states and DC (51 rows).
- Wyoming has no 2025 1-year B25127 row, so state-level mobile-home adjustments were not used; the national adjustment uses the US row only.
- Census completions by region start in 1968; they were used only to test the 1970s weight (table t6), not for the 1960s.
- Two copies of CPSC Publication 516 were opened (cpsc.gov/s3fs-public/516.pdf and /pdfs/516.pdf); their text matched apart from hyphenation, and the first is cited.
- One unsourced per-device COPALUM price on a home inspection page was dropped because it named no source (see excluded.md).
Methodology
Source selection: federal agencies first (Census, CPSC, National Bureau of Standards, USGS), then state agency forms and insurer filings, then two trade bodies (IAEI, NEMA) for product standard history. Commercial blogs and contractor pages were read only as pages to beat.
Era estimate: ACS 2025 1-year table B25034 gives housing units by decade built for 50 states and DC. Each state's 1960s count was multiplied by its Census region's share of 1960s private starts that fell in 1965 to 1969, and its 1970s count by the share of 1970s starts in 1970 to 1973. Starts were used because Census completions by region begin only in 1968.
Owner-occupied and structure-type figures use B25036 and B25127 from the same release. B25127 is not published for Wyoming in the 2025 1-year file, so structure shares are used only at the national level.
Conflicts: CPSC gives two bounds, before 1972 for its survey and the mid 1970s for installation; the brief's 1965 to 1973 window sits between them, and table t6 shows the 1965 to 1972 and 1965 to 1975 alternatives. Insurer files were coded once each by searching the full text for 'aluminum'.
Limitations: no federal survey asks what metal a home's wiring is, so no state count of aluminum-wired homes exists. ACS year built is self-reported. Maine insurer files are dated filings that may have been replaced.
Last updated 2026-11-08. ACS 2025 1-year data were released 2026-10-29.
This report presents published data with its limitations. It is not legal, financial or investment advice.
Sources, ranked by quality
Tier 1: primary and official sources (24)
- [1] U.S. Census Bureau. American Community Survey 2025 1-year, Table B25034 Year Structure Built. 2025. Accessed 2026-11-08.
- [2] U.S. Census Bureau. American Community Survey 2025 1-year, Table B25036 Tenure by Year Structure Built. 2025. Accessed 2026-11-08.
- [3] U.S. Census Bureau. American Community Survey 2025 1-year, Table B25127 Tenure by Year Built by Units in Structure. 2025. Accessed 2026-11-08.
- [4] U.S. Census Bureau. 2025 ACS Data Release Schedule. 2025 ACS releases. Accessed 2026-11-08.
- [5] U.S. Census Bureau. New Residential Construction: New Privately-Owned Housing Units Started, annual by region. 1959 to 2025. Accessed 2026-11-08.
- [6] U.S. Census Bureau. New Residential Construction: New Privately-Owned Housing Units Completed, annual by region. 1968 to 2025. Accessed 2026-11-08.
- [7] U.S. Consumer Product Safety Commission. Repairing Aluminum Wiring, Publication 516 (June 2011). June 2011. Accessed 2026-11-08.
- [8] U.S. Consumer Product Safety Commission. Record of Commission Action: CPSC Publication No. 516, Repairing Aluminum Wiring (ballot due March 21, 2011). March 2011. Accessed 2026-11-08.
- [9] National Bureau of Standards (now NIST). Observations on the Mechanisms of High Resistance Junction Formation in Aluminum Wire Connections, Journal of Research Vol. 85 No. 6 (1980). 1980. Accessed 2026-11-08.
- [10] U.S. Geological Survey. Copper Statistics, Historical Statistics for Mineral and Material Commodities (Data Series 140), last modified June 27, 2023. 1900 to 2020. Accessed 2026-11-08.
- [11] U.S. Geological Survey. Aluminum Statistics, Historical Statistics for Mineral and Material Commodities (Data Series 140), last modified July 5, 2023. 1900 to 2021. Accessed 2026-11-08.
- [12] Citizens Property Insurance Corporation (Florida). 4-Point Inspection Form, Sample Form Insp4pt 01 18. Form edition 01 18. Accessed 2026-11-08.
- [13] State Farm via Maine Bureau of Insurance (Internet Archive). State Farm Underwriting Guidelines, Homeowners, Maine (effective 1/1/2023); Internet Archive capture of the maine.gov file. Effective January 1, 2023. Accessed 2026-11-08.
- [14] Hanover Insurance Group via Maine Bureau of Insurance (Internet Archive). Hanover, Maine Homeowners Underwriting Guidelines (effective 12/03/2018); Internet Archive capture of the maine.gov file. Effective December 3, 2018. Accessed 2026-11-08.
- [15] Integon National via Maine Bureau of Insurance (Internet Archive). Integon National Insurance Company, Maine Homeowners OneChoice (revised April 25, 2019); Internet Archive capture of the maine.gov file. Revised April 25, 2019. Accessed 2026-11-08.
- [16] Integon National via Maine Bureau of Insurance (Internet Archive). Integon National Insurance Company, Homeowners Guidelines OneChoice and Premier Client, Maine (undated); Internet Archive capture of the maine.gov file. Undated. Accessed 2026-11-08.
- [17] Farmers via Maine Bureau of Insurance (Internet Archive). Farmers Property and Casualty Insurance Company, Maine Homeowner New Business Underwriting Guidelines (October 5, 2021); Internet Archive capture. October 5, 2021. Accessed 2026-11-08.
- [18] Farmers via Maine Bureau of Insurance (Internet Archive). Farmers Casualty Insurance Company (FCAS), Maine Homeowner Underwriting Guidelines; Internet Archive capture. December 9, 2022. Accessed 2026-11-08.
- [19] USAA via Maine Bureau of Insurance (Internet Archive). USAA Group Homeowners Insurance Underwriting Guidelines, Maine (Rev. Eff. 02/24/2023); Internet Archive capture. Effective February 24, 2023. Accessed 2026-11-08.
- [20] Chubb via Maine Bureau of Insurance (Internet Archive). Homeowners Underwriting Guidelines, State: Maine (effective 08/01/2022), Chubb writing companies; Internet Archive capture. Effective August 1, 2022. Accessed 2026-11-08.
- [21] Unnamed insurer via Maine Bureau of Insurance (Internet Archive). Maine Homeowners New Business Eligibility and Pricing Guidelines, form PL-12430 (01-07), insurer not named; Internet Archive capture. Form edition 01-07. Accessed 2026-11-08.
- [22] Texas Real Estate Commission. Seller's Disclosure Notice, TREC No. 55-1 (effective 05/28/2026). Effective May 28, 2026. Accessed 2026-11-08.
- [23] Louisiana Real Estate Commission. Residential Property Disclosure Document (01/2026). January 2026 edition. Accessed 2026-11-08.
- [24] Washington State Legislature. RCW 64.06.020 Improved residential real property, seller's duties, format of disclosure statement. Current statute as accessed. Accessed 2026-11-08.
Tier 2: trade bodies, market research, company data (2)
- [25] International Association of Electrical Inspectors. Aluminum Building Wire Installation and Terminations, IAEI Magazine (January/February 2006). January/February 2006. Accessed 2026-11-08.
- [26] National Electrical Manufacturers Association (Internet Archive). The Evolution of Aluminum Conductors Used for Building Wire and Cable (2012); Internet Archive capture. 2012. Accessed 2026-11-08.