Tankless vs Tank Water Heater: Rated Efficiency and Running Cost by State
- Primary data
- ENERGY STAR certified gas water heaters (6sbi-yuk2), EIA-861M and EIA residential gas prices, EIA RECS 2020
- Data period
- Prices September 2025 to August 2026; listings as of 2026-11-13; household survey 2020
- Latest release used
- 2026-11-13
- Next release
- EIA monthly prices about the last week of each month; ENERGY STAR lists update weekly
- Geography
- United States, 50 states and DC
- Sources
- 20 (17 Tier 1)
$172 a year is what a certified gas tankless heater saves over a minimum-efficiency 50-gallon gas tank on DOE's 84-gallon test day, at US prices from September 2025 to August 2026. That tankless vs tank water heater gap falls to $19 against a condensing gas tank and runs from $85 in Idaho to $600 in Hawaii.
Tankless vs tank water heater running cost: $335 against $507 a year on DOE's test day
On the federal test day a certified gas tankless costs $172 a year less to run than a minimum 50-gallon gas tank at US prices for September 2025 to August 2026.
DOE's test procedure fixes the hot water load so that ratings compare: the high-usage pattern draws 84 gallons a day and heats it 67 F, from 58 F to 125 F (10 CFR 430, appendix E). That load is 16,926,773 Btu a year, or 169.27 therms delivered. Dividing by each type's uniform energy factor (UEF) gives the fuel it burns.
Uniform energy factor (UEF): The federal efficiency rating for a water heater: useful heat delivered divided by energy used over the 24-hour test, including standby loss for tanks. A gas unit at 0.95 turns 95% of the gas into hot water on the test day.
A minimum 50-gallon gas tank (UEF 0.627 at high draw under 10 CFR 430.32(d)) burns 270.0 therms. The ENERGY STAR median gas tankless (UEF 0.95, 395 high-usage listings) burns 178.2. At $1.879 a therm, the US mean of monthly EIA residential prices for September 2025 to August 2026, those are $507 and $335 a year.
DOE high-usage test day, prices Sep 2025 to Aug 2026
Source: KBR analysis of ENERGY STAR listings, 10 CFR 430.32, EIA prices
| Type | UEF | Basis | Energy a year | US cost a year |
|---|---|---|---|---|
| Gas tank, federal minimum (50 gal) | 0.627 | 10 CFR 430.32(d)(1) formula | 270.0 therms | $507 |
| Gas tank, 2029 minimum (50 gal) | 0.6774 | 10 CFR 430.32(d)(2) formula | 249.9 therms | $470 |
| Gas tankless, federal minimum | 0.81 | 10 CFR 430.32(d)(1) | 209.0 therms | $393 |
| Gas tank, ENERGY STAR median | 0.9 | Median of 70 US listings | 188.1 therms | $353 |
| Gas tankless, ENERGY STAR median | 0.95 | Median of 395 US listings | 178.2 therms | $335 |
| Electric tank, federal minimum (50 gal) | 0.9299 | 10 CFR 430.32(d)(1) formula | 5,335 kWh | $963 |
| Electric tankless, federal minimum | 0.92 | 10 CFR 430.32(d)(1) | 5,392 kWh | $974 |
| Heat pump tank, ENERGY STAR median | 3.8 | Median of 308 US listings | 1,305 kWh | $236 |
84 gallons a day heated 67 F. Prices: 12-month means, September 2025 to August 2026 ($1.879 a therm, 18.06 cents a kWh). Fans and controls on gas units are not counted.
Source: [1][2][4][5][6][7][8] U.S. EPA ENERGY STAR; U.S. EPA ENERGY STAR; Office of the Federal Register, eCFR; Office of the Federal Register, eCFR; U.S. Energy Information Administration; U.S. Energy Information Administration; U.S. Energy Information Administration
The heat pump tank row is a reference point only: its economics against electric and gas tanks are in the heat pump water heater report.
A condensing gas tank closes most of the gap: UEF 0.90 against 0.95
Of the $172 the certified tankless saves over a minimum tank, $153 is also available from an ENERGY STAR condensing tank; the tankless adds $19.
ENERGY STAR lists 70 US gas tanks, all power vented or power direct vented, with a median UEF of 0.90 and a median first-hour rating of 91.5 gallons (ENERGY STAR, rows updated 2026-11-13). On the same test day that tank burns 188.1 therms and costs $353 a year in the US, $19 more than the median tankless.
Measured that way, the efficiency step that matters is condensing versus non-condensing combustion. Minimum against minimum, a non-condensing tankless (UEF 0.81) saves $115 a year, 22.6% of the gas. ENERGY STAR tankless against ENERGY STAR tank, the saving is 5.3% of the gas.
| Type | Listings | High-usage listings | Median UEF | UEF range | Delivery rating |
|---|---|---|---|---|---|
| Gas tankless | 397 | 395 | 0.95 | 0.95 to 0.98 | Max flow median 5.4 gpm (3.8 to 6.0) |
| Gas tank (storage) | 70 | 70 | 0.9 | 0.88 to 0.9 | First-hour median 91.5 gal; volume median 44.5 gal |
| Residential-duty commercial gas tank | 64 | 64 | 0.88 | 0.86 to 0.93 | Input over 75,000 Btu/h |
Dataset rows updated 2026-11-13; 75 Canada-only listings excluded.
Source: [1] U.S. EPA ENERGY STAR
Hawaii saves $600 a year with a certified gas tankless, Idaho $85
Because every state runs the same test-day load, the state ranking of tankless savings is a ranking of residential gas prices.
The signature figure of this report applies the 91.8 therms a year that an ENERGY STAR median tankless saves over a minimum 50-gallon tank to each state's 12-month mean gas price (EIA, converted with each state's 2025 heat content). Hawaii, at $6.54 a therm, saves $600 a year. Georgia ($252), Texas ($248), Massachusetts ($247) and Florida ($242) follow. Idaho, at $0.927 a therm, saves $85.
Dollars a year on DOE's 84-gallon test day
Source: KBR analysis of ENERGY STAR, 10 CFR 430.32 and EIA gas prices
In 16 jurisdictions the saving is $200 or more. Against an ENERGY STAR condensing tank, no state outside Hawaii gains more than $27 a year from going tankless.
Show all 52 rows
| State | Gas $/therm | Minimum gas tank | ENERGY STAR tankless | Saving vs minimum tank | Saving vs ENERGY STAR tank | Electric tankless (minimum) | Rank |
|---|---|---|---|---|---|---|---|
| Hawaii | 6.540 | $1766 | $1165 | $600 | $65 | $2393 | 1 |
| Georgia | 2.745 | $741 | $489 | $252 | $27 | $814 | 2 |
| Texas | 2.701 | $729 | $481 | $248 | $27 | $864 | 3 |
| Massachusetts | 2.686 | $725 | $479 | $247 | $27 | $1636 | 4 |
| Florida | 2.634 | $711 | $469 | $242 | $26 | $833 | 5 |
| Arkansas | 2.629 | $710 | $468 | $241 | $26 | $731 | 6 |
| Oklahoma | 2.490 | $672 | $444 | $229 | $25 | $739 | 7 |
| Maine | 2.445 | $660 | $436 | $224 | $24 | $1595 | 8 |
| North Carolina | 2.376 | $641 | $423 | $218 | $24 | $803 | 9 |
| Delaware | 2.314 | $625 | $412 | $212 | $23 | $977 | 10 |
| Kentucky | 2.293 | $619 | $409 | $211 | $23 | $755 | 11 |
| Ohio | 2.301 | $621 | $410 | $211 | $23 | $994 | 12 |
| Mississippi | 2.292 | $619 | $408 | $210 | $23 | $808 | 13 |
| South Carolina | 2.236 | $604 | $398 | $205 | $22 | $854 | 14 |
| Missouri | 2.207 | $596 | $393 | $203 | $22 | $748 | 15 |
| New Hampshire | 2.185 | $590 | $389 | $201 | $22 | $1456 | 16 |
| Arizona | 2.153 | $581 | $384 | $198 | $21 | $834 | 17 |
| New York | 2.145 | $579 | $382 | $197 | $21 | $1539 | 18 |
| Vermont | 2.150 | $580 | $383 | $197 | $21 | $1293 | 19 |
| Louisiana | 2.131 | $575 | $380 | $196 | $21 | $706 | 20 |
| California | 2.129 | $575 | $379 | $195 | $21 | $1757 | 21 |
| District of Columbia | 2.128 | $574 | $379 | $195 | $21 | $1318 | 22 |
| Rhode Island | 2.125 | $574 | $379 | $195 | $21 | $1593 | 23 |
| Virginia | 2.109 | $569 | $376 | $194 | $21 | $901 | 24 |
| Alabama | 2.053 | $554 | $366 | $188 | $20 | $889 | 25 |
| Kansas | 2.022 | $546 | $360 | $186 | $20 | $815 | 26 |
| Connecticut | 2.012 | $543 | $358 | $185 | $20 | $1494 | 27 |
| West Virginia | 1.991 | $538 | $355 | $183 | $20 | $847 | 28 |
| Pennsylvania | 1.936 | $523 | $345 | $178 | $19 | $1127 | 29 |
| Maryland | 1.873 | $506 | $334 | $172 | $19 | $1150 | 30 |
| Washington | 1.810 | $489 | $322 | $166 | $18 | $768 | 31 |
| Oregon | 1.780 | $481 | $317 | $163 | $18 | $842 | 32 |
| Tennessee | 1.627 | $439 | $290 | $149 | $16 | $739 | 33 |
| Wyoming | 1.626 | $439 | $290 | $149 | $16 | $763 | 34 |
| Nebraska | 1.596 | $431 | $284 | $146 | $16 | $688 | 35 |
| New Jersey | 1.557 | $420 | $277 | $143 | $15 | $1270 | 36 |
| Indiana | 1.526 | $412 | $272 | $140 | $15 | $917 | 37 |
| Alaska | 1.476 | $398 | $263 | $135 | $15 | $1463 | 38 |
| Iowa | 1.461 | $394 | $260 | $134 | $14 | $763 | 39 |
| Illinois | 1.447 | $391 | $258 | $133 | $14 | $1028 | 40 |
| North Dakota | 1.433 | $387 | $255 | $132 | $14 | $677 | 41 |
| Michigan | 1.329 | $359 | $237 | $122 | $13 | $1143 | 42 |
| Wisconsin | 1.296 | $350 | $231 | $119 | $13 | $1014 | 43 |
| Colorado | 1.222 | $330 | $218 | $112 | $12 | $893 | 44 |
| Minnesota | 1.208 | $326 | $215 | $111 | $12 | $879 | 45 |
| Nevada | 1.207 | $326 | $215 | $111 | $12 | $737 | 46 |
| South Dakota | 1.175 | $317 | $209 | $108 | $12 | $773 | 47 |
| New Mexico | 1.120 | $302 | $200 | $103 | $11 | $819 | 48 |
| Utah | 1.084 | $293 | $193 | $100 | $11 | $715 | 49 |
| Montana | 0.974 | $263 | $173 | $89 | $10 | $757 | 50 |
| Idaho | 0.927 | $250 | $165 | $85 | $9 | $689 | 51 |
| United States | 1.879 | $507 | $335 | $172 | $19 | $974 |
DOE high-usage test day; 16 states had one or more withheld monthly gas prices filled from the same month a year earlier.
Source: [1][4][5][6][7][8] U.S. EPA ENERGY STAR; Office of the Federal Register, eCFR; Office of the Federal Register, eCFR; U.S. Energy Information Administration; U.S. Energy Information Administration; U.S. Energy Information Administration
Electric tankless saves nothing on paper: its floor of 0.92 sits below an electric tank's 0.9299
Electric resistance heats water at close to 100% either way, so the tank's standby loss is small next to the price of electricity.
The federal floor for an electric tankless under 2 gallons at high draw is UEF 0.92; for a 50-gallon electric tank it is 0.9349 – 0.0001 x 50, or 0.9299. At minimums the tankless uses 5,392 kWh a year against 5,335, and at 18.06 cents a kWh it costs $974 against $963, $11 more.
Fuel matters more than format. An ENERGY STAR gas tankless costs $639 a year less to run than a minimum electric tankless in the US, and less in every one of the 51 jurisdictions. From 2029-05-06, most 20 to 55 gallon electric tanks must reach UEF 2.30, a level only heat pump designs meet, while the electric tankless floor stays at 0.92.
| Product class | Floor now | Floor from 2029-05-06 | Withdrawn 2024 tankless rule | ENERGY STAR minimum |
|---|---|---|---|---|
| Gas tank, 20 to 55 gal | 0.6920 – 0.0013 x Vr (0.627 at 50 gal) | 0.7424 – 0.0013 x Veff (0.6774 at 50 gal) | None | 0.86 |
| Gas tankless, over 50,000 Btu/h | 0.81 | No line in the current table | 0.93 (withdrawn 2025-05-20) | 0.95 |
| Electric tank, 20 to 55 gal | 0.9349 – 0.0001 x Vr (0.9299 at 50 gal) | 2.30 (heat pump level) | None | Heat pump criteria only |
| Electric tankless, under 2 gal | 0.92 | 0.92 | None | Not covered |
eCFR up to date as of 2026-11-17. Vr and Veff are rated and effective storage volume in gallons.
Source: [3][4][13][14] U.S. EPA ENERGY STAR; Office of the Federal Register, eCFR; U.S. Department of Energy, Federal Register; U.S. Department of Energy, Federal Register
6.5% of US homes had a tankless main heater in 2020, and 18.0% of homes built 2016 to 2020
Tankless heaters were still a small share of the housing stock in 2020, but they were concentrated in the newest homes and the newest installations.
In EIA's 2020 Residential Energy Consumption Survey, 1,347 of 18,496 sampled households reported a tankless or on-demand main water heater (WHEATSIZ = 4). Weighted, that is 6.5% of homes, 8.03 million, with a standard error of 0.23 points (RECS 2020).
Main water heater is tankless or on-demand
Source: KBR analysis of EIA RECS 2020 microdata
The share was 18.0% in homes built 2016 to 2020, 2.8 times the national share, and 12.0% among heaters less than 2 years old, against 3.5% among heaters 20 years or older. By region it ran from 4.3% in the Midwest to 9.1% in the Northeast; New England alone reached 15.2%.

Fuel oil and propane homes report tankless heaters four to seven times as often as electric homes
Of the 8.03 million tankless homes in 2020, 48.5% used natural gas and 30.0% electricity, but the tankless share was highest among fuel oil and propane users.
28.5% of homes heating water with fuel oil and 23.7% of propane homes reported a tankless main heater, against 6.6% of natural gas homes and 4.2% of electric homes (RECS 2020). RECS records what households report, and the codebook does not separate stand-alone tankless units from water heated on demand by a boiler, which is a plausible reading of the fuel oil figure in New England. KBR did not test that reading.
Share of homes using each fuel for the main heater
Source: KBR analysis of EIA RECS 2020 microdata
Show all 32 rows
| Group | Category | Tankless share % | Standard error (pts) | Tankless homes (millions) | Sample cases |
|---|---|---|---|---|---|
| All | United States | 6.5 | 0.23 | 8.03 | 1347 |
| Region | Northeast | 9.1 | 0.46 | 1.99 | 424 |
| Region | Midwest | 4.3 | 0.39 | 1.17 | 160 |
| Region | South | 5.5 | 0.3 | 2.6 | 385 |
| Region | West | 8.2 | 0.55 | 2.26 | 378 |
| Fuel | Electricity | 4.2 | 0.27 | 2.41 | 366 |
| Fuel | Natural gas | 6.6 | 0.3 | 3.89 | 620 |
| Fuel | Propane | 23.7 | 1.73 | 0.98 | 187 |
| Fuel | Fuel oil | 28.5 | 2.02 | 0.75 | 174 |
| Housing type | Mobile home | 2.6 | 0.6 | 0.18 | 30 |
| Housing type | Single-family detached | 7.6 | 0.3 | 5.84 | 1029 |
| Housing type | Single-family attached | 5.2 | 0.64 | 0.39 | 106 |
| Housing type | Apartment, 2 to 4 units | 2.7 | 0.63 | 0.25 | 28 |
| Housing type | Apartment, 5+ units | 6.0 | 0.55 | 1.37 | 154 |
| Year built | Before 1950 | 7.9 | 0.61 | 1.6 | 227 |
| Year built | 1950 to 1959 | 6.1 | 0.67 | 0.76 | 110 |
| Year built | 1960 to 1969 | 5.8 | 0.56 | 0.74 | 122 |
| Year built | 1970 to 1979 | 5.1 | 0.53 | 0.94 | 164 |
| Year built | 1980 to 1989 | 4.6 | 0.46 | 0.75 | 134 |
| Year built | 1990 to 1999 | 5.6 | 0.49 | 0.96 | 151 |
| Year built | 2000 to 2009 | 4.9 | 0.49 | 0.79 | 151 |
| Year built | 2010 to 2015 | 12.0 | 1.18 | 0.66 | 119 |
| Year built | 2016 to 2020 | 18.0 | 1.44 | 0.82 | 169 |
| Heater age | Under 2 years | 12.0 | 0.65 | 2.11 | 351 |
| Heater age | 2 to 4 years | 8.4 | 0.55 | 1.89 | 313 |
| Heater age | 5 to 9 years | 5.8 | 0.38 | 2.27 | 355 |
| Heater age | 10 to 14 years | 4.6 | 0.35 | 1.16 | 205 |
| Heater age | 15 to 19 years | 2.7 | 0.45 | 0.28 | 53 |
| Heater age | 20 years or more | 3.5 | 0.46 | 0.31 | 70 |
| Division | East North Central | 3.8 | 0.45 | 0.71 | 74 |
| Division | New England | 15.2 | 0.96 | 0.89 | 283 |
| Division | Pacific | 9.0 | 0.69 | 1.67 | 231 |
RECS 2020 WHEATSIZ = 4 (tankless or on-demand), weighted with NWEIGHT; jackknife standard errors from 60 replicate weights.
Source: [9][10][11] U.S. Energy Information Administration; U.S. Energy Information Administration; U.S. Energy Information Administration
Can a tankless water heater run two showers? 66.7% of certified models can, all hot, at test temperatures
Rated flow is measured at a 67 F rise; colder inlet water and mixing with cold water move the answer in opposite directions.
The median of 396 US ENERGY STAR gas tankless listings is rated 5.4 gpm, from 3.8 to 6.0. Two showers at the federal 2.5 gpm limit need 5.0 gpm if both ran all hot; 66.7% of models are rated for that. A shower mixed to 105 F draws only part of its flow from the heater: 0.70 of it at test temperatures, so the median unit carries about 3.1 mixed showers and 100.0% of models carry two.
With 40 F winter inlet water the same burner manages a 85 F rise, so the median capacity falls to 4.26 gpm and the hot share of a mixed shower rises to 0.76. The median unit then carries about 2.2 mixed showers, 66.9% of models carry two, and none carries two all-hot showers. The 105 F mix and 40 F inlet are KBR assumptions for illustration. Sizing by household is covered in what size water heater; fixture flow rates in shower water use and kitchen faucet gpm.
Share of 396 gas tankless listings by fixture load
Source: KBR analysis of ENERGY STAR gas tankless listings
| Fixtures running at once | Hot demand at 58 F inlet (gpm) | Models that cover it, 58 F inlet % | Hot demand at 40 F inlet (gpm) | Models that cover it, 40 F inlet % |
|---|---|---|---|---|
| One 2.5 gpm shower, all hot | 2.50 | 100.0 | 2.50 | 100.0 |
| Two 2.5 gpm showers, all hot | 5.00 | 66.7 | 5.00 | 0.0 |
| Two 2.5 gpm showers mixed to 105 F | 3.51 | 100.0 | 3.82 | 66.9 |
| Three 2.5 gpm showers mixed to 105 F | 5.26 | 59.6 | 5.74 | 0.0 |
| Two mixed showers plus a 2.2 gpm kitchen faucet, all hot | 5.71 | 34.6 | 6.02 | 0.0 |
396 US ENERGY STAR gas tankless listings with a max GPM. Ratings are at a 67 F rise; the 40 F inlet case scales capacity by 67/85. The 105 F shower mix and 40 F inlet are KBR assumptions.
Source: [1][4][5] U.S. EPA ENERGY STAR; Office of the Federal Register, eCFR; Office of the Federal Register, eCFR
DOE's own figures: 8% to 14% savings for heavy users, and a withdrawn condensing rule
DOE's consumer guidance put tankless gains lower than the rating comparison here, and its 2024 attempt to require condensing tankless units no longer has force.
DOE's Energy Saver page said demand water heaters can be 24% to 34% more efficient than storage tanks for homes using 41 gallons or less a day, and 8% to 14% more efficient for homes using about 86 gallons a day (Internet Archive capture of 2026-06-30). The page does not say which ratings it compared. On today's certified ratings, a minimum tankless uses 22.6% less gas than a minimum tank at 84 gallons a day, more than the page's range for heavy users.
DOE's December 2024 rule would have required gas tankless units to reach UEF 0.93 at high draw, a condensing level, from 2029-12-26. Its analysis put a non-condensing tankless at $2,087 installed with a $303 first-year operating cost, and a level 2 condensing unit at $2,318 and $277, an 8.9-year simple payback (2023 dollars, 89 FR 105188). A joint resolution of disapproval was signed on 2025-05-09 and DOE withdrew the rule on 2025-05-20 (90 FR 21390).

Is a tankless water heater worth it? The test-day saving covers a typical price gap in 2.6 to 5.3 years
Whether a tankless pays depends on the price premium, the gas price and how much hot water the home uses; the test day is a heavy-use case.
Fixr, an undated cost guide, lists $590 to $700 installed for a 50-gallon tank and $1,140 to $1,500 for a tankless unit. At the US test-day saving of $172 a year, that gap takes 2.6 to 5.3 years to recover, undiscounted. Scaled to DOE's 55-gallon medium draw, the saving is about $113 and the range 3.9 to 8.1 years. Against an ENERGY STAR condensing tank the $19 saving would recover little of any premium.
These figures exclude venting, gas line and electrical work that a swap may need, which is a cost item in a bathroom remodel cost budget, and they do not count maintenance such as descaling. DOE's average lifetimes, about 20 years for gas tankless and 14 to 15 years for gas tanks, are discussed in the water heater lifetime report. Setpoint effects are in water heater temperature.
Ratios behind the comparison
Signature: yearly saving of a certified gas tankless over a minimum gas tank, by state
Formula(169.27 / 0.627 - 169.27 / 0.95) therms x state 12-month mean $/therm; 169.27 = 365 x 84 x 8.24 x 1.00 x 67 / 100,000
Inputs: fact rows for draw, density, specific heat, rise, federal gas tank formula, ENERGY STAR median UEF, state gas prices and heat content; derived d1 to d3, sig (fact sheet rows)
Result: $172 a year US; $85 (Idaho) to $600 (Hawaii); 16 jurisdictions at $200 or more
The same 91.8 therms is saved everywhere on the test day, so the ranking follows gas prices. Outside Hawaii the top four are Georgia, Texas, Massachusetts and Florida.
Limitations: Test-day load, not metered use; simple mean of monthly prices; 16 states had withheld months backfilled; minimum tank is a 50-gallon high-draw unit.
How much of the tankless advantage is condensing
Formulasaving vs ENERGY STAR tank / saving vs minimum tank = 19 / 172; gas saving 1 - 0.90 / 0.95
Inputs: ENERGY STAR median UEFs for gas tank and gas tankless, US gas price (fact sheet rows)
Result: $19 a year, 5.3% of gas
A condensing tank captures most of the gain that a condensing tankless shows over a non-condensing tank.
Limitations: ENERGY STAR medians only; non-condensing tankless models are not in the ENERGY STAR list.
Electric tankless vs electric tank at federal minimums
Formula(16,926,773 / 0.92 - 16,926,773 / 0.9299) / 3,412.14 x 18.06 cents
Inputs: federal floors, DOE test load, US electricity price (fact sheet rows)
Result: $11 a year more for the tankless
On ratings, the electric tankless has no running cost edge over a resistance tank.
Limitations: Many electric tankless models test above the 0.92 floor; CCMS listings were not available to measure that.
Tankless share of homes by year built and heater age
Formulasum NWEIGHT[WHEATSIZ = 4 and group] / sum NWEIGHT[group]; SE = sqrt(59/60 x sum (replicate - full)^2)
Inputs: RECS 2020 v7 microdata, 18,496 households (fact sheet rows)
Result: 6.5% all homes; 18.0% built 2016 to 2020; 12.0% of heaters under 2 years
New construction and recent replacements chose tankless at roughly two to three times the stock rate.
Limitations: 2020 data; household-reported type; 23.3% of tankless responses were imputed.
Fixture coverage of certified tankless models at two inlet temperatures
Formulashare of listings with max GPM x 67 / rise >= fixture demand; mixed demand = 2.5 x (105 - inlet) / (125 - inlet)
Inputs: 396 ENERGY STAR max GPM ratings, federal 2.5 gpm showerhead and 2.2 gpm kitchen faucet limits, assumed 105 F mix and 40 F inlet (fact sheet rows)
Result: Two mixed showers: 100.0% of models at 58 F inlet, 66.9% at 40 F; two all-hot showers: 66.7% and 0.0%
Winter inlet temperature, not rated flow alone, decides whether two showers run at once.
Limitations: Assumes fixed heat output; real showerheads often flow below 2.5 gpm.
Where the numbers diverge
- An ENERGY STAR median gas tankless (UEF 0.95) uses 178.2 therms a year on DOE's 84-gallon test day, against 270.0 for a minimum 50-gallon gas tank (UEF 0.627), 34.0% less gas (KBR analysis, 2026).[1][4][5]
- At the US mean gas price of $1.879 a therm for September 2025 to August 2026, the tankless costs $335 a year and the minimum tank $507, a $172 difference.[7][8]
- Against the ENERGY STAR median gas tank (UEF 0.90, 70 US listings, November 2026) the tankless saves 5.3% of gas, $19 a year in the US.[1][7]
- A minimum-efficiency gas tankless (UEF 0.81) saves $115 a year over a minimum tank in the US, 22.6% less gas.[4][7]
- Hawaii shows the largest saving, $600 a year at $6.54 a therm; Idaho the smallest, $85 at $0.927 a therm, a 7.1 times spread (2025 to 2026 prices).[7][8]
- Outside Hawaii, Georgia ($252), Texas ($248), Massachusetts ($247) and Florida ($242) post the largest yearly savings over a minimum gas tank.[7][8]
- When the 2029 federal floor lifts a 50-gallon gas tank to UEF 0.6774, the US saving shrinks to $135 a year at current prices.[4][7]
- The electric tankless floor (UEF 0.92) is below the 50-gallon electric tank floor (0.9299); at minimums the tankless costs $11 a year more in the US.[4][6]
- In all 51 jurisdictions an ENERGY STAR gas tankless costs less to run than a minimum electric tankless; the US gap is $639 a year.[1][4][6][7]
- 6.5% of US homes had a tankless main water heater in 2020 (standard error 0.23 points), 8.03 million homes (RECS 2020, KBR analysis).[9][11]
- The tankless share was 18.0% in homes built 2016 to 2020 and 15.2% in New England, against 4.3% in the Midwest (RECS 2020).[9]
- Fuel oil (28.5%) and propane (23.7%) homes reported tankless heaters far more often than natural gas (6.6%) or electric (4.2%) homes in 2020.[9][10]
- The median ENERGY STAR gas tankless is rated 5.4 gpm at a 67 F rise; 66.7% of 396 listings can run two 2.5 gpm showers all hot at test temperatures.[1][4][5]
- DOE put the average installed cost of a non-condensing gas tankless at $2,087 and its first-year operating cost at $303 (2023 dollars, December 2024 rule).[14]
Summary
- On DOE's high-usage test day (84 gallons a day, heated 67 F), a minimum 50-gallon gas tank burns 270.0 therms a year and an ENERGY STAR median gas tankless burns 178.2, a 34.0% cut.
- At the US mean residential gas price of $1.879 a therm (September 2025 to August 2026), that is $507 against $335 a year, a $172 saving.
- Most of that gap is condensing versus non-condensing, not tank versus tankless: the ENERGY STAR median gas tank rates UEF 0.90 and costs $353, only $19 more than the tankless.
- Gas prices set the state ranking: the saving over a minimum tank is $600 in Hawaii, $252 in Georgia and $85 in Idaho; 16 jurisdictions clear $200.
- Electric tankless has no rated edge: its federal floor (0.92) sits below the 50-gallon electric tank floor (0.9299), and at minimums it costs $974 a year against $963.
- In 2020, 6.5% of US homes (8.03 million) had a tankless main heater; the share was 18.0% in homes built 2016 to 2020 and 12.0% among heaters under 2 years old.
- The median certified gas tankless unit is rated 5.4 gpm, which covers about 3.1 showers mixed to 105 F at test temperatures but about 2.2 with 40 F winter inlet water (KBR assumptions).
Questions people ask
Is a tankless water heater worth it?
On DOE's 84-gallon test day, an ENERGY STAR gas tankless saves $172 a year over a minimum gas tank at 2025 to 2026 US prices, which covers Fixr's listed price gap in 2.6 to 5.3 years; at medium draw the range is 3.9 to 8.1 years. Against a condensing tank the saving is $19 a year.
How long do tankless water heaters last?
DOE's December 2024 rule analysis used an average lifetime of 20.0 years for gas tankless units and about 14 to 15 years for gas tanks; DOE's Energy Saver page said more than 20 years. See the water heater lifetime report.
Can a tankless heater run two showers?
At test temperatures 66.7% of 396 certified gas tankless models can run two 2.5 gpm showers all hot, and all can run two showers mixed to 105 F. With 40 F inlet water, 66.9% can run two mixed showers (KBR assumptions).
For journalists and researchers
If you cite only a few, cite these
- A certified gas tankless water heater saves $172 a year over a minimum 50-gallon gas tank on DOE's test day at 2025 to 2026 US gas prices (KBR analysis).[1][4][7]
- Against an ENERGY STAR condensing gas tank, the same tankless saves $19 a year in the US.[1][7]
- 18.0% of US homes built 2016 to 2020 had a tankless main water heater, against 6.5% of all homes (RECS 2020, KBR analysis).[9]
Most quotable statistics
- A certified gas tankless water heater saves $172 a year over a minimum 50-gallon gas tank on DOE's test day at 2025 to 2026 US gas prices (KBR analysis).[1][4][7]
- Against an ENERGY STAR condensing gas tank, the same tankless saves $19 a year in the US.[1][7]
- The yearly saving from a gas tankless runs from $85 in Idaho to $600 in Hawaii, set by state gas prices.[7][8]
- 18.0% of US homes built 2016 to 2020 had a tankless main water heater, against 6.5% of all homes (RECS 2020, KBR analysis).[9]
- At federal minimum ratings, an electric tankless costs $11 a year more to run than a 50-gallon electric tank.[4][6]
- With 40 F inlet water, none of 396 certified gas tankless models can run two 2.5 gpm showers all hot (KBR analysis).[1]
Press summary
A KBR analysis of ENERGY STAR certified water heaters and 12 months of EIA state energy prices finds that a gas tankless water heater at the certified median efficiency (UEF 0.95) costs $335 a year to run on DOE's 84-gallon test day, against $507 for a minimum-efficiency 50-gallon gas tank, a $172 saving. Most of that gap comes from condensing combustion: an ENERGY STAR condensing gas tank (UEF 0.90) costs $353, only $19 more than the tankless. By state, the saving over a minimum tank ranges from $85 in Idaho to $600 in Hawaii, with Georgia, Texas, Massachusetts and Florida next. Electric tankless units show no rated advantage: at federal minimums they cost $974 a year against $963 for an electric tank. EIA's 2020 household survey shows 6.5% of US homes with a tankless main heater, rising to 18.0% in homes built 2016 to 2020. Prices cover September 2025 to August 2026.
Suggested headlines
- Gas tankless water heaters save $172 a year over basic tanks, $19 over condensing tanks
- Hawaii gains $600 a year from a gas tankless heater, Idaho $85
- Electric tankless water heaters show no rated savings over electric tanks
- 18.0% of new US homes had a tankless water heater by 2020
- Most of a tankless heater's edge comes from condensing, not from losing the tank
How to cite this report
Kitchen and Bath Renovators. (2026). Tankless vs Tank Water Heater: Rated Efficiency and Running Cost by State. Retrieved from https://kitchenandbathrenovators.com/research/tankless-vs-tank-water-heater/
Reuse license
Data and tables are licensed CC BY 4.0. Attribution: “Source: Kitchen and Bath Renovators, Tankless vs Tank Water Heater: Rated Efficiency and Running Cost by State” with a link to this page.
Download the data
Every table in this report is available as a CSV under CC BY 4.0. The fact sheet lists each value with its source URL and access date.
- derived_metrics.csv (CSV)
- fact_sheet.csv (CSV)
- Rated efficiency and US yearly energy cost by water heater type, DOE high-usage test day (CSV)
- Yearly running cost and savings by state: certified gas tankless vs gas tank (CSV)
- Share of US homes whose main water heater is tankless, 2020 (CSV)
- Share of certified gas tankless models that can carry each fixture combination (CSV)
- Federal efficiency floors and ENERGY STAR thresholds, high draw pattern (CSV)
- ENERGY STAR certified gas water heaters on the US market, November 2026 (CSV)
Frequently asked questions
How much does a gas tankless water heater cost to run a year?
$335 a year in the US for the ENERGY STAR median model (UEF 0.95) on DOE's 84-gallon test day, at $1.879 a therm (September 2025 to August 2026).
How much does a standard gas tank cost to run?
$507 a year for a minimum 50-gallon gas tank (UEF 0.627) on the same test day and prices, or $353 for an ENERGY STAR condensing tank (UEF 0.90).
Which state saves the most with a gas tankless?
Hawaii, $600 a year over a minimum gas tank at $6.54 a therm. Georgia is second at $252.
Which state saves the least?
Idaho, $85 a year at $0.927 a therm, followed by Montana and Utah.
Is an electric tankless cheaper to run than an electric tank?
Not on federal minimum ratings: $974 against $963 a year in the US, because the tankless floor (UEF 0.92) is below the 50-gallon tank floor (0.9299).
How common are tankless water heaters?
6.5% of US homes, 8.03 million, had a tankless main water heater in 2020 (EIA RECS, KBR analysis); 18.0% of homes built 2016 to 2020 did.
What flow rate does a certified gas tankless deliver?
The median of 396 US ENERGY STAR listings is 5.4 gpm at a 67 F rise, with a range of 3.8 to 6.0 gpm (November 2026).
What UEF must a gas tankless reach for ENERGY STAR?
0.95 or higher, plus at least 2.8 gpm over a 67 F rise. The federal floor is 0.81.
Did DOE ban non-condensing tankless water heaters?
No. A December 2024 rule would have required UEF 0.93 at high draw from 2029-12-26, but DOE withdrew it on 2025-05-20 after a congressional disapproval.
Will the 2029 gas tank standard change the comparison?
Yes, modestly: a 50-gallon gas tank must reach UEF 0.6774 from 2029-05-06, which cuts the US tankless saving from $172 to $135 a year at current prices.
Reproduce this analysis
Every figure comes from the files below. The scripts that pulled and computed them are kept with the report and can be re-run.
| Dataset | Publisher | Source | Query or filter | Rows used | Retrieved |
|---|---|---|---|---|---|
| ENERGY STAR Certified Gas (Storage and Tankless) Water Heaters | U.S. EPA | File or endpoint | Markets contains United States; Draw Pattern = High-Usage for UEF medians; Type in Gas Tankless, Gas Storage | 531 US listings; 395 tankless and 70 tank at high usage | 2026-11-19 |
| ENERGY STAR Certified Heat Pump Water Heaters | U.S. EPA | File or endpoint | Markets contains United States; High-Usage | 308 | 2026-11-19 |
| 10 CFR 430.32 and appendix E | eCFR | File or endpoint | Paragraph (d) tables 1 and 14; (o); (p); appendix E sections 5.3.2, 6.3.9, 6.4.5 | 8 product-class formulas | 2026-11-19 |
| EIA-861M sales and revenue | EIA | File or endpoint | Monthly-States sheet, residential columns, 2025-09 to 2026-08 | 612 state-months | 2026-11-19 |
| Natural gas residential price by state, monthly | EIA | File or endpoint | Data 1 sheet, 2025-09 to 2026-08, backfill from 2024 and 2023 where withheld | 51 states plus US, 12 months each | 2026-11-19 |
| Heat content of natural gas delivered to consumers | EIA | File or endpoint | Data 1 sheet, 2025 row | 52 | 2026-11-19 |
| RECS 2020 public microdata v7 (shared copy: build/kitchenandbathrenovators.com/research_shared/recs2020/recs2020_public_v7.csv) | EIA | File or endpoint | WHEATSIZ = 4 by REGIONC, DIVISION, FUELH2O, TYPEHUQ, YEARMADERANGE, WHEATAGE; NWEIGHT and NWEIGHT1 to NWEIGHT60 | 18,496 households | 2026-11-19 |
Data quality and exclusions
- Dropped 75 Canada-only ENERGY STAR gas listings of 606.
- Excluded 2 of 397 US tankless listings from the UEF median because they are not rated on the high-usage pattern (1 medium, 1 blank).
- 1 tankless listing has no max GPM value, so fixture shares use 396 listings.
- One ENERGY STAR listing shows 2 therms a year, an apparent entry error; therm figures in this report are computed from UEF, not taken from that field.
- 16 states had withheld monthly residential gas prices in the 12-month window; each gap was filled with the same month one or two years earlier (Florida needed 8 such months).
- In RECS, 23.3% of weighted tankless responses were imputed by EIA; they are kept, as EIA recommends for estimates.
- Of RECS tankless homes, 15.4% share a heater serving several units (weighted); they are kept in the household share.
Methodology
Source selection: federal and federally run sources only for data (ENERGY STAR certified lists, eCFR, Federal Register, EIA price files and RECS microdata). Three consumer cost guides were opened as pages to beat; one (Fixr) supplies a price range used only for an illustrative payback and is labelled Tier 3.
Efficiency inputs: the ENERGY STAR gas water heater dataset (rows updated 2026-11-13) was filtered to listings sold in the US (531 of 606) and to the high-usage draw pattern, the pattern on which 395 of 397 tankless listings are rated. Federal floors come from 10 CFR 430.32(d) as of 2026-11-17, evaluated at 50 gallons for tanks. DOE's certification database (CCMS), which would include non-condensing models, returned HTTP 403 and was not used.
Cost model: annual heat = 365 x 84 x 8.24 x 1.00 x 67 Btu (appendix E, sections 6.3.9 and 6.4.5); fuel = heat / UEF; cost = fuel x price. Listed ENERGY STAR therms match this formula to a median of 0.18 therms, which confirms the load.
Prices: electricity is the mean of 12 monthly residential prices (revenue / sales) from EIA-861M, September 2025 to August 2026; gas is the mean of 12 monthly residential $/Mcf from EIA, converted to $/therm with each state's 2025 heat content. Simple means are used because water heating load is close to flat across the year; volume-weighted means would weight winter months and give lower gas prices. Where EIA withheld a monthly gas price (16 states), the same month one year earlier, or two if needed, filled the gap.
Household shares: RECS 2020 v7 microdata, read from the shared copy, with WHEATSIZ = 4 as tankless, NWEIGHT for estimates and 60 jackknife replicate weights for standard errors (variance = 59/60 x sum of squared deviations), per EIA's microdata guide. RECS 2024 v1 has no water heater variables, so RECS 2020 is the latest source.
Conflicts: DOE's Energy Saver ranges (8% to 14% for heavy users) differ from the rating comparison here (22.6% minimum to minimum); both are reported, and the difference is attributed to unstated comparison ratings, not resolved.
Limitations and last update: test-day loads exceed many homes' use, ENERGY STAR medians are listing medians rather than sales-weighted, and fixture scenarios use assumed temperatures. Last updated 2026-11-19.
This report presents published data with its limitations. It is not legal, financial or investment advice.
Sources, ranked by quality
Tier 1: primary and official sources (17)
- [1] U.S. EPA ENERGY STAR. ENERGY STAR Certified Gas (Storage and Tankless) Water Heaters, dataset 6sbi-yuk2 (rows updated 2026-11-13). Listings as of 2026-11-13. Accessed 2026-11-19.
- [2] U.S. EPA ENERGY STAR. ENERGY STAR Certified Heat Pump Water Heaters, dataset v7jr-74b4. Listings as of 2026-11-19. Accessed 2026-11-19.
- [3] U.S. EPA ENERGY STAR. ENERGY STAR Water Heater Key Product Criteria. Current criteria. Accessed 2026-11-19.
- [4] Office of the Federal Register, eCFR. 10 CFR 430.32(d), (o) and (p): energy conservation standards for water heaters, faucets and showerheads (eCFR, up to date as of 2026-11-17). As of 2026-11-17. Accessed 2026-11-19.
- [5] Office of the Federal Register, eCFR. Appendix E to Subpart B of 10 CFR Part 430: Uniform Test Method for Measuring the Energy Consumption of Water Heaters (eCFR). As of 2026-11-17. Accessed 2026-11-19.
- [6] U.S. Energy Information Administration. Form EIA-861M monthly sales and revenue by state (sales_revenue.xlsx). September 2025 to August 2026. Accessed 2026-11-19.
- [7] U.S. Energy Information Administration. Natural Gas Prices: price delivered to residential consumers by state, monthly. September 2023 to August 2026 (backfill years included). Accessed 2026-11-19.
- [8] U.S. Energy Information Administration. Heat content of natural gas delivered to consumers by state, annual. 2025. Accessed 2026-11-19.
- [9] U.S. Energy Information Administration. 2020 Residential Energy Consumption Survey (RECS) public use microdata, version 7. 2020. Accessed 2026-11-19.
- [10] U.S. Energy Information Administration. RECS 2020 Codebook for Public File, v7 (WHEATSIZ, FUELH2O, WHEATAGE, YEARMADERANGE). 2020. Accessed 2026-11-19.
- [11] U.S. Energy Information Administration. Using the 2020 RECS microdata file to compute estimates and standard errors. 2020 survey. Accessed 2026-11-19.
- [12] U.S. Energy Information Administration. 2024 RECS microdata page (housing characteristics release May 2026) and 2024 codebook v1. 2024. Accessed 2026-11-19.
- [13] U.S. Department of Energy, Federal Register. Energy Conservation Standards for Consumer Gas-Fired Instantaneous Water Heaters; final rule, withdrawal (90 FR 21390). 2025-05-20. Accessed 2026-11-19.
- [14] U.S. Department of Energy, Federal Register. Energy Conservation Standards for Consumer Gas-fired Instantaneous Water Heaters; final rule (89 FR 105188), full text. 2024-12-26 (2023 dollars). Accessed 2026-11-19.
- [15] U.S. Department of Energy, Federal Register. Energy Conservation Standards for Consumer Water Heaters; final rule (89 FR 37778), document metadata. 2024-05-06. Accessed 2026-11-19.
- [16] U.S. Department of Energy. Consumer Water Heaters, Appliance and Equipment Standards product page. Current page. Accessed 2026-11-19.
- [17] U.S. Department of Energy. Energy Saver: Tankless or Demand-Type Water Heaters (Internet Archive capture of 2026-06-30; the live page returned not found in a 2026-10-31 capture). Page as captured 2026-06-30. Accessed 2026-11-19.
Tier 3: journalism and expert commentary (3)
- [18] Bob Vila. Tank vs. Tankless Water Heater Cost: 8 Factors to Consider (updated 2025-07-08). 2025. Accessed 2026-11-19.
- [19] Fixr. Tank vs Tankless Water Heater: pros, cons, comparisons and costs. Undated. Accessed 2026-11-19.
- [20] WIN Home Inspection. Tank vs Tankless Water Heater: Pros, Cons, Comparison and Costs. Undated. Accessed 2026-11-19.